正在加载图片...
樊玮洁等:电化学修复后钢筋混凝土黏结性能演变规律 781· 70 70 (a) (b) % 60 40 0 30 30 20 -I0-D0 20 I0-D0 -11-D7 ·-I3-D7 10 -I1-D15 o I3-D15 +-I1-D28 I3-D28 0 2 4 6 0 2 6 Average displacement/mm Average displacement/mm (c) % 30 20 +-I10-D0 I5-D7 10 I5-D15 +-I5-D28 0 2 6 Average displacement/mm 图4不同电流密度下的黏结-滑移曲线.(a)1Am:(b)3Am2:(c)5Am2 Fig.4 Bond force-slip curves under different current densities:(a)1 A'm (b)3 A-m (c)5 A.m 表3拉拔实验最大黏结力 49.24 50 ★ 9 ●-50.16 Table 3 Maximum force of pull-out test 50.29 ■ 45.58 45 47.66 Maximum force/kN Average Average Average bond 4331 38.9 Sample force/kN stress/ reduced % Sample 1 Sample 2 Sample 3 MPa value puoq ★0d ●7d I0-D0 44.34 54.72 51.80 50.29 16.34 1.000 A15d I1-D7 50.16 50.58 49.76 50.17 16.30 0.998 ■28d I1-D1549.21 49.8649.54 49.54 16.10 0.985 25 21.69 I1-D28 46.81 45.69 50.49 47.66 15.49 0.948 20 2 6 13-D749.06 49.6851.74 50.16 16.04 0.997 Current density/(A'm-2) I3-D15 42.41 48.50 45.83 45.58 12.45 0.906 图5不同电流密度下的最大黏结力 I3-D2842.15 42.9144.86 4331 14.07 0.861 Fig.5 Maximum bond force under different currents densities I5-D747.18 49.2051.34 4924 16.00 0.979 60 I5-D1535.11 39.0642.54 56.86%▲ 38.9012.64 0.774 -■-7d I5-D2817.7127.8019.57 50 21.69 7.70 0.431 -●-15d ▲-28d 表现出高敏感性:电流密度为5Am-2通电28d的 试件,最大黏结力损失率高达56.9%.综上所述,除 22.64% 去通电时间为7d的三组试件,黏结力损失量随电 20 ● 13.87% 流密度这一变量增加呈指数增长趋势 0 5.22% 9.36% 1.49%. 2.08% 2.2通电时间对钢筋混凝土黏结性能的影响 0.25% 0: 023% -■ 实验设置中通电时间分别为7,15和28d,图7 4 6 Current density/(A-m) 为不同通电时间下的最大黏结力.可以看出在相 图6不同电流密度下最大黏结力损失量 同的电流密度下,随着通电时间的增加,最大黏结 Fig.6 Maximum bond force loss amount under different current 力呈现出减小趋势,且通电7d内最大黏结力的减 densities表现出高敏感性;电流密度为 5 A·m–2 通电 28 d 的 试件,最大黏结力损失率高达 56.9%. 综上所述,除 去通电时间为 7 d 的三组试件,黏结力损失量随电 流密度这一变量增加呈指数增长趋势. 2.2    通电时间对钢筋混凝土黏结性能的影响 实验设置中通电时间分别为 7,15 和 28 d,图 7 为不同通电时间下的最大黏结力. 可以看出在相 同的电流密度下,随着通电时间的增加,最大黏结 力呈现出减小趋势,且通电 7 d 内最大黏结力的减 表 3    拉拔实验最大黏结力 Table 3    Maximum force of pull-out test Sample Maximum force/kN Average force/kN Average bond stress/ MPa Average reduced Sample 1 Sample 2 Sample 3 value I0-D0 44.34 54.72 51.80 50.29 16.34 1.000 I1-D7 50.16 50.58 49.76 50.17 16.30 0.998 I1-D15 49.21 49.86 49.54 49.54 16.10 0.985 I1-D28 46.81 45.69 50.49 47.66 15.49 0.948 I3-D7 49.06 49.68 51.74 50.16 16.04 0.997 I3-D15 42.41 48.50 45.83 45.58 12.45 0.906 I3-D28 42.15 42.91 44.86 43.31 14.07 0.861 I5-D7 47.18 49.20 51.34 49.24 16.00 0.979 I5-D15 35.11 39.06 42.54 38.90 12.64 0.774 I5-D28 17.71 27.80 19.57 21.69 7.70 0.431 0 2 4 6 0 10 20 30 40 50 60 70 (a) Bond force/kN Average displacement/mm I0-D0 I1-D7 I1-D15 I1-D28 0 2 4 6 0 10 20 30 40 50 60 70 (b) Bond force/kN Average displacement/mm I0-D0 I3-D7 I3-D15 I3-D28 0 2 4 6 0 10 20 30 40 50 60 70 (c) Bond force/kN Average displacement/mm I0-D0 I5-D7 I5-D15 I5-D28 图 4    不同电流密度下的黏结–滑移曲线. (a)1 A·m–2;(b)3 A·m–2;(c)5 A·m–2 Fig.4    Bond force–slip curves under different current densities: (a) 1 A·m−2; (b) 3 A·m−2; (c) 5 A·m−2 0 2 4 6 20 25 30 35 40 45 50 Maximum bond force/kN Current density/(A·m−2) 0 d 7 d 15 d 28 d 49.24 38.9 21.69 43.31 45.58 50.16 50.17 49.54 47.66 50.29 图 5    不同电流密度下的最大黏结力 Fig.5    Maximum bond force under different currents densities 0 2 4 6 0 10 20 30 40 50 60 Bond force loss/ % 7 d 15 d 28 d 56.86% 22.64% 13.87% 5.22% 9.36% 2.08% 0.25% 1.49% 0.23% Current density/(A·m−2) 图 6    不同电流密度下最大黏结力损失量 Fig.6     Maximum  bond  force  loss  amount  under  different  current densities 樊玮洁等: 电化学修复后钢筋混凝土黏结性能演变规律 · 781 ·
<<向上翻页向下翻页>>
©2008-现在 cucdc.com 高等教育资讯网 版权所有