CFX! Rules for solids in domains Each solid in the domain/Sub-domain specification must be a valid cFx- Build solid Solids may not overlap one another If there is more than one bounding solid defining the Domain/Sub- domain, each solid must be connected at a common solid face(point or edge contact is not allowed) Cutout solids must lie wholly within the regions defined by the bounding solids ofthe domain/sub-domain The connection of a cutout solid with a bounding solid must be at a common solid face Multiplecutout solids can be used If cutout solids are connected to each other they must do so at common solid faces Sub-domains must lie wholly within the regions defined by the domain The connection ofa Sub-domain with a domain must be at a common solid face CFX5.5 V5.5.1H 2001AEA TechnologyCFX 5.5 V5.5.1H © 2001AEA Technology 5-3 Rules for Solids in Domains Each solid in the Domain/Sub-domain specification must be a valid CFX￾Build solid. Solids may not overlap one another. If there is more than one bounding solid defining the Domain/Sub￾domain, each solid must be connected at a common solid face (point or edge contact is not allowed). Cutout solids must lie wholly within the regions defined by the bounding solids of the Domain/Sub-domain. The connection of a cutout solid with a bounding solid must be at a common solid face. Multiple cutout solids can be used. If cutout solids are connected to each other they must do so at common solid faces. Sub-domains must lie wholly within the regions defined by the Domain. The connection of a Sub-domain with a Domain must be at a common solid face