正在加载图片...
Model name Mac capacity Spindle speed PC-3000 utility Fireball EL 5.400 quel.exe Fireball EX EX Pcquex.exe Fireball cr CR 13.0 5400 Pcqucr.exe Fireball CX 20.4 5.400 P Fireball lct08(LA)Lcto8 26.0 5.400 Fireball lct10(LB)Lct10 30.0 5.400 Pcplct 10exe Fireball lct15(LC) Lct15 5400 Pcplct 15exe Fireball lct20(LD) Lct20 40.0 5.400 Pcplct20.exe Maxtor D540X-4K MX4KxxxHx 80.0 5,400 Pcmx540k . exe Fireball Plus Ka 7.200 Pcquka. exe Fireball Plus KX X 273 7200 Pcqukx.exe Fireball Plus lm LM 30.0 7,200 Pcqulm.exe Fireball Plus as AS 60.0 7.200 P quas. exe Maxtor D740X-6L MX6LXXXJx 80.0 7 200 Pcmx7401. exe 3. Basic options for repair of Quantum drives The PC-3000 package utilities for the above-listed drives provide for the following repair drive testing in factory mode restoration of the drive hardware service data; reading of the drive's rom restoration and correction of the drive ID area(logical parameters, model name, serial number) ● low level format e modification of the drive configuration (isolation of defective surfaces, isolation of defective areas) modification of cache configuration, ECC control and automatic defects relocation; review and checking of the service data structure loading of a program for service data access(LDr file); review of hidden defects tables review of drive S M.A. R.T. table and resetting it to factory defaults physical and logical surface scanning for defects, and, based on the results, addition of evealed defects to the defects table hiding of defective tracks creation of an automatic surface testing routine for a drive and running it launch of a drives self-testing routine (SELFSCAN) 4. Preparation for work Connect the PC-3000PRo tester cable to the ide connector of the drive being tested Connect the power cable to the drive being tested Switch on the power. If a PC-3K PWr power supply adapter is present, the power supply is switched on automatically at utility start. Power may be switched on without turning the PC offFamily Model name Mac.capacity Spindle speed, rpm PC-3000 utility Fireball EL EL 10.2 5,400 Pcquel.exe Fireball EX EX 12.7 5,400 Pcquex.exe Fireball CR CR 13.0 5,400 Pcqucr.exe Fireball CX CX 20.4 5,400 Pcqucx.exe Fireball lct08(LA) Lct08 26.0 5,400 Pcplct08.exe Fireball lct10(LB) Lct10 30.0 5,400 Pcplct10.exe Fireball lct15(LC) Lct15 30.0 5,400 Pcplct15.exe Fireball lct20(LD) Lct20 40.0 5,400 Pcplct20.exe Maxtor D540X-4K MX4KxxxHx 80.0 5,400 Pcmx540k..exe Fireball Plus KA KA 18.2 7,200 Pcquka.exe Fireball Plus KX KX 27.3 7,200 Pcqukx.exe Fireball Plus LM LM 30.0 7,200 Pcqulm.exe Fireball Plus AS AS 60.0 7,200 Pcquas.exe Maxtor D740X-6L MX6LxxxJx 80.0 7,200 Pcmx740l.exe 3. Basic options for repair of Quantum drives The PC-3000 package utilities for the above-listed drives provide for the following repair operations: ⚫ drive testing in factory mode; ⚫ restoration of the drive hardware service data; ⚫ reading of the drive’s ROM; ⚫ restoration and correction of the drive ID area (logical parameters, model name, serial number); ⚫ low level format; ⚫ modification of the drive configuration (isolation of defective surfaces, isolation of defective areas); ⚫ modification of cache configuration, ECC control and automatic defects’ relocation; ⚫ review and checking of the service data structure; ⚫ loading of a program for service data access (LDR file); ⚫ review of hidden defects tables; ⚫ review of drive S.M.A.R.T. table and resetting it to factory defaults; ⚫ physical and logical surface scanning for defects, and, based on the results, addition of revealed defects to the defects table; ⚫ hiding of defective sectors; ⚫ hiding of defective tracks; ⚫ creation of an automatic surface testing routine for a drive and running it; ⚫ launch of a drive’s self-testing routine (SELFSCAN). 4. Preparation for work. -Connect the PC-3000PRO tester cable to the IDE connector of the drive being tested. -Connect the power cable to the drive being tested. -Switch on the power. If a PC-3K PWR power supply adapter is present, the power supply is switched on automatically at utility start. Power may be switched on without turning the PC off
<<向上翻页向下翻页>>
©2008-现在 cucdc.com 高等教育资讯网 版权所有