正在加载图片...
first. Damage to the PC-3000 PRO controller in that mode is unlikely; however its output cascades may be damaged in cases when a burnt-out electronic board is connected Start a utility corresponding to the connected drive's family using the shell. com command shell for convenience auxiliary utility files are located in the same directory with the utilities. Please see details regarding auxiliary files in Section 10 Attention! Utility tests have lots of options. It is recommended that novice users work with default test options 5. Utility usage 5. 1 Launching the utility After utility start it reads a drives ID area. If a drive does not process the command for ID area reading the following error message appears: Unidentified logical drive parameters Default values used-"Final LBA=1000 Then a"Model selection"window appears, where you should select the model for the connected drive. After model selection the utility will read the 8 configuration page and verif the number of magnetic heads for the selected model and the connected drive. In case of mismatch the following message appears Model adjusted according to the number of physically present head If a drive does not allow reading the 8 configuration page the following message will Error reading CP#8 (page containing the number of physically present heads) Then and analysis of connected heads is performed(CP14)together with the zone allocation table(CP10). In case of errors the following messages are output Error reading CP#14(heads control page) Error reading CP#f10 (zone allocation page) Errors arising in the process of initialization are ignored and parameters that could not be recovered from the drive are replaced with default values, which may lead to incorrect operation of surface testing routines. After initialization the program will bring up the main operating modes menu Surface scanning Firmware data Drive Id SM.ARTtable Defects table Automatic mode SELFSCAN 5.2 Servo testfirst. Damage to the PC-3000 PRO controller in that mode is unlikely; however its output cascades may be damaged in cases when a burnt-out electronic board is connected. -Start a utility corresponding to the connected drive’s family using the shell.com command shell for convenience. -Auxiliary utility files are located in the same directory with the utilities. Please see details regarding auxiliary files in Section 10. Attention! Utility tests have lots of options. It is recommended that novice users work with default test options. 5. Utility usage. 5.1 Launching the utility After utility start it reads a drive’s ID area. If a drive does not process the command for ID area reading the following error message appears: Unidentified logical drive parameters Default values used-“Final LBA”=1000 Then a “Model selection” window appears, where you should select the model for the connected drive. After model selection the utility will read the 8th configuration page and verify the number of magnetic heads for the selected model and the connected drive. In case of mismatch the following message appears: Model adjusted according to the number of physically present head If a drive does not allow reading the 8th configuration page the following message will appear. Error reading CP#8 (page containing the number of physically present heads) Then and analysis of connected heads is performed (CP14) together with the zone allocation table (CP10). In case of errors the following messages are output: Error reading CP#14 (heads control page) Error reading CP#10 (zone allocation page) Errors arising in the process of initialization are ignored and parameters that could not be recovered from the drive are replaced with default values, which may lead to incorrect operation of surface testing routines. After initialization the program will bring up the main operating modes menu: Servo test Surface scanning Firmware data Drive ID Logical scanning S.M.A.R.T.table Defects table Automatic mode SELFSCAN Exit 5.2 Servo test
<<向上翻页向下翻页>>
©2008-现在 cucdc.com 高等教育资讯网 版权所有