正在加载图片...
Sing pt Bud] Single Canti lever Bending Geometry→“ Edit Geometry”→“ Frame size”选“ Medium(2mm)”,“ Center Clamp”选“ Medium(6mm)”, Length:8.0 为默认值,不用改动),用游标卡尺量取样品的宽、厚尺寸,并填入相应的栏中 (样条尺寸30×10×15左右),“ Tool serial Num”中填“0000”。 (7)“ options”→“ Tool Thermal Expansion coefficient”栏中填“00”;“ Fixture Compliance”栏中填“0.0”;“ Toll mass”栏中填“13.lg”→ok→ok。 (8)‘ Test set up”选‘ Predefined Test Set Up",“Test”选[ D temp Ramp]( Dynamic Temperatune Ramp Test)→“ Edit test”→“ Frequency”栏中填“1.0”H,"“ Initial Temp”填“200”,“ Final Temp”填“120.0″,“ Ramp Rate”填“2.5”,“ Soak Time after Ramp”填“0”,“ Time Per measure”填“l”,“ Strain”填“0.05”。 (9)“ option”→不选,即在“ Delay Before Test”,“ Auto tension Adjustment”和 Measure Option”三个选择项前均无“十”号→“ok”→“ok (10)“ end of test”=“ turn off temp controller”设为“NO”,“ Turn OFF MOTOR” 设为“NO”,“ turn hold on”设为“NO”→ok (11)“test”中选“ strain- control”,“ Measure”中选“ Dynamic”。 (12)“ Load sample”,在DMTA的TBAR上安装“ straight clamp support”。在四根 支架上安装“ wide Face Frame Bar”和“ Medium clamp”,并上好螺母。 (13)“ continue”→仪器自动零点校正→用10cN·M的扭力扳手安装样品,同 时要保证软件窗口中标尺的读数的绝对值小于0.001,还要保证炉子关闭时,样条 不会触及护壁→“DONE”→合上炉子。 (14)等待温度示值稳定后,“ Begin Test” (15)“ layout”→“ Plot layout”→“ layout”中选lemp为X轴,E’、E”为 Y-left 轴,tand为 Y-right轴;“ scaling”中把两个Y轴设为对数坐标,X轴为线性坐标, 在“ color/ symbols/ lines”中选取不同的颜色和线性 (16)试验结束后,卸下全部的夹具及样品,并关闭软件,最后关闭DMTA电源。 五、实验结果及分析: DMIA-V动态粘弹仪自动处理数据并打印出谱图。学生要学会通过动态粘弹 谱曲线分析问题: (1)分析在实验温度范围内,聚合物模量变化的趋势并说明原因。 (2)分析比较共混聚合物结构特点及两相相容的情况。 六、问题讨论: (1)如何通过动态粘弹试验评价共混或复合材料的相容性? (2)如何判断共混材料中的连续相或分散相? (3)为什么在玻璃化转变区内tand会出现最大值?[Sing Pt Bud]Single Canti lever Bending Geometry “Edit Geometry”“Frame size”选“Medium(2mm)”,“Center Clamp”选“Medium(6mm)”,Length:8.0 (为默认值,不用改动),用游标卡尺量取样品的宽、厚尺寸,并填入相应的栏中 (样条尺寸 30×10×l.5 左右),“Tool serial Num”中填“0000”。 (7)“options” “Tool Thermal Expansion coefficient”栏中填“0.0”;“Fixture Compliance”栏中填“0.0”;“Toll mass”栏中填“13.1g” ok  ok。 (8)‘Test set up”选‘Predefined Test Set Up”,“Test”选[D temp Ramp](Dynamic Temperatune Ramp Test) “Edit test”“Frequency”栏中填“1.0”HZ,“Initial Temp”填“20.0”,“Final Temp”填“120.0”,“Ramp Rate”填“2.5”,“Soak Time after Ramp”填“0”,“Time Per Measure”填“l”,“Strain”填“0.05”。 (9)“option” 不选,即在“Delay Before Test”,“Auto tension Adjustment”和 “Measure Option”三个选择项前均无“+”号 “ok”“ok”。 (10)“end of test”=“turn off temp controller”设为“NO”,“Turn OFF MOTOR” 设为“NO”,“turn hold on”设为“NO” ok。 (11)“test”中选“strain-control”,“Measure”中选“Dynamic”。 (12)“Load sample”,在 DMTA 的 T-BAR 上安装“straight clamp support”。在四根 支架上安装“wide Face Frame Bar”和“Medium clamp”,并上好螺母。 (13)“continue”  仪器自动零点校正  用 10cN·M 的扭力扳手安装样品,同 时要保证软件窗口中标尺的读数的绝对值小于 0.001,还要保证炉子关闭时,样条 不会触及护壁 “DONE” 合上炉子。 (14)等待温度示值稳定后,“Begin Test” (15)“layout”“Plot layout”“layout”中选 Temp 为 X 轴, E 、E 为 Y-left 轴, tan 为 Y-right 轴;“scaling”中把两个 Y 轴设为对数坐标,X 轴为线性坐标, 在“color/symbols/lines”中选取不同的颜色和线性。 (16)试验结束后,卸下全部的夹具及样品,并关闭软件,最后关闭 DMTA 电源。 五、实验结果及分析: DMTA-IV 动态粘弹仪自动处理数据并打印出谱图。学生要学会通过动态粘弹 谱曲线分析问题: (1)分析在实验温度范围内,聚合物模量变化的趋势并说明原因。 (2)分析比较共混聚合物结构特点及两相相容的情况。 六、问题讨论: (1)如何通过动态粘弹试验评价共混或复合材料的相容性? (2)如何判断共混材料中的连续相或分散相? (3)为什么在玻璃化转变区内 tan 会出现最大值?
<<向上翻页向下翻页>>
©2008-现在 cucdc.com 高等教育资讯网 版权所有