nature INSIGHTI REVIEW ARTICLES materials PUBLISHED ONLINE:24 MARCH 2009|DOI:10.1038/NMAT2399 Near-edge X-ray absorption fine-structure microscopy of organic and magnetic materials Harald Ade*and Herman Stoll2 Many high-performance materials and novel devices consist of multiple components and are naturally or intentionally nano- structured for optimal properties and performance.To understand their structure-property relationships fully,quantitative compositional analysis at length scales below 100 nm is required,a need that is often uniquely addressed using soft X-ray microscopy.Similarly,the interaction of X-rays with magnetic materials provides unique element-specific contrast that allows the determination of magnetic properties in multi-element antiferromagnetic and ferromagnetic materials.Pump-probe-type experiments can even investigate magnetic domain dynamics.Here we review and exemplify the ability of soft X-ray micro- scopy to provide information that is otherwise inaccessible,and discuss a perspective on future developments. ithout contrast,any inherent spatial resolution from bioapplications to materials characterization occurred for of a microscope is useless.It is thus the contrast photoelectron emission microscopy (PEEM)15.The main step mechanism that often imparts unique capabilities to a towards materials characterization was the combination of soft microscopy technique.Such uniqueness can be provided by the X-ray absorption spectroscopy techniques with transmission and specific interaction of soft X-rays with matter.Most fruitful is the surface instruments25.The resulting NEXAFS microscopy provides exploitation of the absorption process of a soft X-ray photon near an a unique combination of contrast mechanism,interaction cross- absorption edge,that is,near-edge X-ray absorption fine-structure section,spatial resolution and relatively low sample damage56. (NEXAFS)spectroscopy,as the detailed dependence of absorption on photon energy reveals much of the electronic structure-core Contrast mechanism and instrument parameters and unoccupied valence states-of the material investigated 2.This Examples of NEXAFS spectroscopy that illustrate its ability to provides excellent quantitative elemental and functional sensitivity characterize composition and magnetic properties are displayed in and,if coupled to the polarization state of the photons,can also Fig.1.NEXAFS spectroscopy is particularly rich in spectral features characterize bond orientation'and magnetic domain structures. when acquired from organic materials and is especially reveal- Pump-probe-type experiments even allow for very high time ing for magnetic materials when photon polarization effects and resolution and the investigation of magnetic-domain dynamics37. element specificity are used2.In organic materials,NEXAFS shows NEXAFS microscopy,and soft X-ray microscopy in general,is very detailed correlations with specific chemical moieties that can a comparatively young discipline that is still rapidly evolving and often be understood quite well from theoretical calculations or developing.The field is in the transition to an 'industrial stage,in through use of molecular analogues.In conjunction with the polari- which commercial companies emerge to provide for the needs of zation state of the X-rays,the element-specific NEXAFS of magnetic a wide range of users.This led to the very recent decision at the domains shows pronounced dichroism that can be used to infer the Ninth International Conference for X-ray Microscopy (Zurich, domain orientation as well as the specific contribution of an ele- 20-25 July 2008)to shorten the conference cycle of this series from ment to the magnetization.In addition,NEXAFS is sensitive to the three years to two.In this Review,we seek to provide a flavour of orientation of specific chemical orbitals in organic materials this growing field,illustrate capabilities and applications with Zone-plate-based microscopes are of two main types:scanning soft X-rays,and speculate on some future developments.A short transmission X-ray microscopes(STXMs)and transmission X-ray historical context is provided,the physics underlying the contrast microscopes(TXMs).The basic operating principles are similar to mechanism is discussed,and a few applications are selected to the optical or electron microscopy analogues.In the STXM,the illustrate some of the capabilities.Throughout,the focus will be on sample is mechanically raster-scanned through the focal spot pro- characterizing materials with NEXAFS microscopy,most notably vided by a zone plate.In the TXM,a zone plate magnifies the sample organic and magnetic materials. onto a two-dimensional detector.STXMs are routinely operated on grazing-incidence grating monochromators at synchrotron facili- Historical notes ties,and the implementation of NEXAFS microscopy was relatively The development of modern,high-spatial-resolution soft X-ray easy even though zone plates are highly chromatic.Special acqui- microscopes based on zone-plate technology is about three decades sition or analysis tools were developed to avoid potential degrada- olds.Although initially envisioned and developed with the goal of tion of the spatial resolution caused by the need to refocus during imaging live biological samples in their natural,that is,hydrated, changes in energy202.Historically,TXMs have been installed on unfixed and unfrozen,state with suboptical resolution,radia- inflexible zone-plate-based monochromators,and NEXAFS micro- tion damage during exposure necessitated the development of scopy applications have been much more limited.In a PEEM, cryofixation techniques for biological applicationst.Unsurpris- implementation of NEXAFS microscopy is straightforward as ingly,the technology developed has proved to be very useful over only the photon energy needs to be scannedss.Scanning instru- the past 15 years in characterizing a much wider range of materials ments have also been developed to perform spatially resolved than biological samples2.A similar evolutionary broadening X-ray photoemission spectroscopy(XPS)from surfaces 22.XPS Department of Physics,NCSU,Raleigh,North Carolina 27695,USA;2Max-Planck-Institut fur Metallforschung,HeisenbergstraBe 3,70569 Stuttgart, Germany.e-mail:Harald_Ade@ncsu.edu NATURE MATERIALS VOL 8 APRIL 2009 www.nature.com/naturematerials 281 2009 Macmillan Publishers Limited.All rights reserved
nature materials | VOL 8 | APRIL 2009 | www.nature.com/naturematerials 281 insight | review articles Published online: 24 march 2009 | doi: 10.1038/nmat2399 Without contrast, any inherent spatial resolution of a microscope is useless. It is thus the contrast mechanism that often imparts unique capabilities to a microscopy technique. Such uniqueness can be provided by the specific interaction of soft X-rays with matter. Most fruitful is the exploitation of the absorption process of a soft X-ray photon near an absorption edge, that is, near-edge X-ray absorption fine-structure (NEXAFS) spectroscopy, as the detailed dependence of absorption on photon energy reveals much of the electronic structure — core and unoccupied valence states — of the material investigated1,2. This provides excellent quantitative elemental and functional sensitivity3 and, if coupled to the polarization state of the photons, can also characterize bond orientation4 and magnetic domain structure5 . Pump–probe-type experiments even allow for very high time resolution and the investigation of magnetic-domain dynamics6,7. NEXAFS microscopy, and soft X-ray microscopy in general, is a comparatively young discipline that is still rapidly evolving and developing. The field is in the transition to an ‘industrial stage’, in which commercial companies emerge to provide for the needs of a wide range of users. This led to the very recent decision at the Ninth International Conference for X-ray Microscopy (Zurich, 20–25 July 2008) to shorten the conference cycle of this series from three years to two. In this Review, we seek to provide a flavour of this growing field, illustrate capabilities and applications with soft X-rays, and speculate on some future developments. A short historical context is provided, the physics underlying the contrast mechanism is discussed, and a few applications are selected to illustrate some of the capabilities. Throughout, the focus will be on characterizing materials with NEXAFS microscopy, most notably organic and magnetic materials. historical notes The development of modern, high-spatial-resolution soft X-ray microscopes based on zone-plate technology is about three decades old8,9. Although initially envisioned and developed with the goal of imaging live biological samples in their natural, that is, hydrated, unfixed and unfrozen, state with suboptical resolution8,9, radiation damage during exposure necessitated the development of cryofixation techniques for biological applications10. Unsurprisingly, the technology developed has proved to be very useful over the past 15 years in characterizing a much wider range of materials than biological samples3,4,11,12. A similar evolutionary broadening near-edge X-ray absorption fine-structure microscopy of organic and magnetic materials harald ade1 * and herman stoll2 Many high-performance materials and novel devices consist of multiple components and are naturally or intentionally nanostructured for optimal properties and performance. To understand their structure–property relationships fully, quantitative compositional analysis at length scales below 100 nm is required, a need that is often uniquely addressed using soft X-ray microscopy. Similarly, the interaction of X-rays with magnetic materials provides unique element-specific contrast that allows the determination of magnetic properties in multi-element antiferromagnetic and ferromagnetic materials. Pump–probe-type experiments can even investigate magnetic domain dynamics. Here we review and exemplify the ability of soft X-ray microscopy to provide information that is otherwise inaccessible, and discuss a perspective on future developments. from bioapplications to materials characterization occurred for photoelectron emission microscopy (PEEM)5,13–15. The main step towards materials characterization was the combination of soft X-ray absorption spectroscopy techniques with transmission and surface instruments3,15. The resulting NEXAFS microscopy provides a unique combination of contrast mechanism, interaction crosssection, spatial resolution and relatively low sample damage3,15,16. contrast mechanism and instrument parameters Examples of NEXAFS spectroscopy that illustrate its ability to characterize composition and magnetic properties are displayed in Fig. 1. NEXAFS spectroscopy is particularly rich in spectral features when acquired from organic materials1,17,18 and is especially revealing for magnetic materials when photon polarization effects and element specificity are used2 . In organic materials, NEXAFS shows very detailed correlations with specific chemical moieties that can often be understood quite well from theoretical calculations or through use of molecular analogues. In conjunction with the polarization state of the X-rays, the element-specific NEXAFS of magnetic domains shows pronounced dichroism that can be used to infer the domain orientation as well as the specific contribution of an element to the magnetization. In addition, NEXAFS is sensitive to the orientation of specific chemical orbitals in organic materials1,4,19. Zone-plate-based microscopes are of two main types: scanning transmission X-ray microscopes (STXMs) and transmission X-ray microscopes (TXMs). The basic operating principles are similar to the optical or electron microscopy analogues. In the STXM, the sample is mechanically raster-scanned through the focal spot provided by a zone plate. In the TXM, a zone plate magnifies the sample onto a two-dimensional detector. STXMs are routinely operated on grazing-incidence grating monochromators at synchrotron facilities, and the implementation of NEXAFS microscopy was relatively easy even though zone plates are highly chromatic3,4. Special acquisition or analysis tools were developed to avoid potential degradation of the spatial resolution caused by the need to refocus during changes in energy20,21. Historically, TXMs have been installed on inflexible zone-plate-based monochromators, and NEXAFS microscopy applications have been much more limited. In a PEEM, implementation of NEXAFS microscopy is straightforward as only the photon energy needs to be scanned5,15. Scanning instruments have also been developed to perform spatially resolved X-ray photoemission spectroscopy (XPS) from surfaces 22,23. XPS 1 Department of Physics, NCSU, Raleigh, North Carolina 27695, USA; 2 Max-Planck-Institut für Metallforschung, Heisenbergstraβe 3, 70569 Stuttgart, Germany. *e-mail: Harald_Ade@ncsu.edu nmat_2399_APR09.indd 281 13/3/09 11:54:35 © 2009 Macmillan Publishers Limited. All rights reserved
REVIEW ARTICLES INSIGHT NATURE MATERIALS DOL:10.1038/NMAT2399 Polyvinyl 十CH2-CH N~CC -methylketone C=0 CHg C-H Nylon-6 Functional group Polymethyl -methacrylate HC XY =C.N,O Polyurea N 8 Polyurethane Polycarbonate tO-2+ 284 286 288 290 292 Photon energy (eV) X-ray magnetic linear dichroism X-ray magnetic circular dichroism Antiferromagnets Ferromagnets LaFeO, 5- cos-e 720722 724 700 720 740 Photon energy (eV) Photon energy(eV) Figure 1 Illustration of compositional,linear and circular magnetic dichroic contrast mechanisms using NEXAFS spectroscopy.a,NEXAFS spectral features corresponding to the carbonyl group (shown in red)as function of progressive functional group environment (ketone to carbonate)show a systematic shift towards higher energies for a more electronegative environment'.b,Linearly polarized X-rays produce spectral differences,that is,linear dichroism,for parallel or perpendicularly aligned antiferromagnetic domains.c,Circularly polarized light produces spectral differences,that is,circular dichroism,for parallel,perpendicular and antiparallel aligned ferromagnetic domains.Figure courtesy of J.Stohr. microscopy can also be accomplished in a PEEM2.Generally,XPS They are particularly radiation sensitive(chemical changes and mass microscopy has been little used for the characterization of organic loss)owing to the ability of damaging radicals to diffuse rapidly. and magnetic materials. Thus,these materials are an area of application where NEXAFS For organic matter,soft X-rays not only provide excellent com- microscopy has unique advantages when suboptical resolution is positional contrast,but are also about three orders of magnitude required.The first direct,real-space characterization of a new type less damaging than electron energy-loss spectroscopy in trans- of polyvinyl-alcohol-based micro-balloon in aqueous environment mission electron microscopes'.Not surprisingly,a large number (Fig.2)is a good example2s.A six-month-old suspension of the of X-ray microscopy applications involve organic matter in some micro-balloons that contained at least partially degraded balloons form or another.Similarly,numerous magnetic materials have was investigated.Imaging below and above the oxygen K edge,as been investigated as a result of the special contrast mechanism of well as complete NEXAFS analysis of individual micro-balloons, element-specific linear and circular dichroism,and the possibility could provide unique information on the composition of the micro- of studying dynamical phenomena.Material classes,such as tradi- balloons in water.From the oxygen NEXAFS of the micro-balloon tional semiconductors or superconductors and other oxides,have interiors,a distinction between water-and air-filled particles could not been investigated extensively with NEXAFS microscopy so far. be made unambiguously.For example,the NEXAFS spectrum of micro-balloon A in Fig.2a showed only the resonances typical Organics in aqueous environments for the telechelic polyvinyl-alcohol shell,strongly suggesting that Some of the most challenging materials to characterize are organic micro-balloon A is air filled.Furthermore,the micro-balloons A, materials suspended or dispersed in the hydrated,unfrozen state. B and C shown in Fig.2a had total shell thicknesses of 0.38 um, 282 NATURE MATERIALS VOL 8|APRIL 2009 www.nature.com/naturematerials 2009 Macmillan Publishers Limited.All rights reserved
282 nature materials | VOL 8 | APRIL 2009 | www.nature.com/naturematerials review articles | insight NaTure MaTerialS doi: 10.1038/nmat2399 microscopy can also be accomplished in a PEEM24. Generally, XPS microscopy has been little used for the characterization of organic and magnetic materials. For organic matter, soft X-rays not only provide excellent compositional contrast, but are also about three orders of magnitude less damaging than electron energy-loss spectroscopy in transmission electron microscopes16. Not surprisingly, a large number of X-ray microscopy applications involve organic matter in some form or another. Similarly, numerous magnetic materials have been investigated as a result of the special contrast mechanism of element-specific linear and circular dichroism, and the possibility of studying dynamical phenomena. Material classes, such as traditional semiconductors or superconductors and other oxides, have not been investigated extensively with NEXAFS microscopy so far. organics in aqueous environments Some of the most challenging materials to characterize are organic materials suspended or dispersed in the hydrated, unfrozen state. They are particularly radiation sensitive (chemical changes and mass loss) owing to the ability of damaging radicals to diffuse rapidly. Thus, these materials are an area of application where NEXAFS microscopy has unique advantages when suboptical resolution is required. The first direct, real-space characterization of a new type of polyvinyl-alcohol-based micro-balloon in aqueous environment (Fig. 2) is a good example25. A six-month-old suspension of the micro-balloons that contained at least partially degraded balloons was investigated. Imaging below and above the oxygen K edge, as well as complete NEXAFS analysis of individual micro-balloons, could provide unique information on the composition of the microballoons in water. From the oxygen NEXAFS of the micro-balloon interiors, a distinction between water- and air-filled particles could be made unambiguously. For example, the NEXAFS spectrum of micro-balloon A in Fig. 2a showed only the resonances typical for the telechelic polyvinyl-alcohol shell, strongly suggesting that micro-balloon A is air filled. Furthermore, the micro-balloons A, B and C shown in Fig. 2a had total shell thicknesses of 0.38 μm, E X-ray magnetic linear dichroism Antiferromagnets 720 722 724 Photon energy (eV) 4 1 2 3 LaFeO3 L2 Normalized electron yield I | cos2Ѳ Ѳ X-ray magnetic circular dichroism Ferromagnets 700 720 740 0 4 8 Photon energy (eV) Fe L3 L2 Absorption coefficient I | cosѲ Ѳ Photon energy (eV) Polyvinyl -methylketone Nylon-6 Polymethyl -methacrylate Polyurea Polyurethane Polycarbonate C-H Intensity 284 286 288 290 292 C n O O O CH3 CH3 CH2 n CH3 H3C C O C O C n C O * N * H n H CH3 H O C N N C n O O C O N O H N H CH3 CH2 CH3 CH n C O C O C C N C O C C O O C N C O N N C O O C O O N O O Functional group X,Y = C,N,O X O C Y a b c Figure 1 | illustration of compositional, linear and circular magnetic dichroic contrast mechanisms using NeXaFS spectroscopy. a, NEXAFS spectral features corresponding to the carbonyl group (shown in red) as function of progressive functional group environment (ketone to carbonate) show a systematic shift towards higher energies for a more electronegative environment18. b, Linearly polarized X-rays produce spectral differences, that is, linear dichroism, for parallel or perpendicularly aligned antiferromagnetic domains. c, Circularly polarized light produces spectral differences, that is, circular dichroism, for parallel, perpendicular and antiparallel aligned ferromagnetic domains. Figure courtesy of J. Stöhr. nmat_2399_APR09.indd 282 13/3/09 11:54:35 © 2009 Macmillan Publishers Limited. All rights reserved
NATURE MATERIALS DOL:10.1038/NMAT2399 INSIGHT I REVIEW ARTICLES Distance(um) 400nm um Figure 2 NEXAFS imaging of latex particles and microballoons dispersed in water.a,STXM transmission image of microballoons recorded at 520 eV, that is,below the oxygen absorption edge.b,Radial transmittance profiles of micro-balloons A,B and C,labelled as in a.c,Expanded views of micro- balloon shells.d,Three-dimensional representations of the polyacrylate (green)and polystyrene (greyscale)distributions of water-suspended latex particles.Figures reproduced with permission from:a-c,ref.25 2008 RSC:d,ref.28@2007 IUCr. 0.56 um and 0.63 um,respectively.The difference between these water,and each component could be selectively mapped in 3D.As results and the shell thickness of 0.90 um derived from confocal there is no inefficient X-ray optics between the sample and the detec- laser scanning microscopy was explained by the limited resolution tor in a STXM,the dose used to acquire the STXM tomographs was of about 180 nm for this technique,compared with 40-nm reso- only~200 MGy,which is considerably lower than the dose required lution for X-rays.Closer inspection of the shells revealed further for TXM tomography(typically 1-10 GGy).Even so,tomography details(Fig.2c).The increase of the shell thickness is correlated is a relatively high-dose method and the ultimate spatial resolution with the appearance of a fuzzy contour around the polymeric shell might be limited by damage.Unfortunately,cryogenic methods and the loss of air content.Degradation of the polymeric micro- only prevent mass loss and the spectroscopic changes due to chemi- balloons upon aging leads to leakage of the gas filling and is asso- cal damage are essentially unmitigated by cryogenic techniques*. ciated with an increase of the shell thickness.The appearance of a Other studies ofhydrated soft matter include the in situ,real-space fuzzy contour around the polymeric shell of the corrupted micro- determination of the charge state in stimulus-responsive micro- balloons is presumably the result of the partial destruction of the gels",the determination of crosslink density in super-absorbent polymeric network,but further investigations are needed to reveal polymers",density determinations of polyelectrolyte assemblies" the degradation mechanism definitively.The X-ray microscopy and the correlation of metal distributions in organic biofilms3536.The results directly showed that the particular micro-balloon system studies of microgels,crosslink density in super-absorbent polymers, investigated has remarkably high stability.These balloons are able and biofilms made explicit use of NEXAFS spectral differences and to contain gases for six months,which makes them well suited to features,whereas the studies of the polyelectrolyte assemblies relied biomedical applications. primarily on the 'water-window contrast'(at fixed photon energy) As complex materials often have three-dimensional(3D)morph- due to the elemental differences in the cross-sections of carbon ologies,a number of new methods have been developed recently to and oxygen. perform 3D chemical mapping24-2 or 3D morphological mapping of thick,frozen biological samples29.However,of these methods, Organic electronic materials only NEXAFS tomography has high spectroscopic resolution and Owing to their processability from solvents,organic electronic sensitivity,and the ability to analyse wet specimens28.To illustrate materials may yield cheap light-emitting diodes and photovoltaic the present state of the art (achieved with a STXM),the 3D chemical devices.Furthermore,flexible devices can be constructed.Organic composition of structured,hollow latex spheres in an aqueous solu- devices are thus extensively studied by a large number of research tion is presented in Fig.2d.A NEXAFS feature of the acrylate com- groups around the world.Generally,devices are composed of donor ponent just below the onset of the oxygen 1s edge of water was used and acceptor materials that are used in layered thin-film geometries to provide selective contrast between the acrylate,the styrene and that often include one or more buffer layers and the electrodes. NATURE MATERIALS|VOL 8|APRIL 2009 www.nature.com/naturematerials 283 2009 Macmillan Publishers Limited.All rights reserved
nature materials | VOL 8 | APRIL 2009 | www.nature.com/naturematerials 283 NaTure MaTerialS doi: 10.1038/nmat2399 insight | review articles 0.56 μm and 0.63 μm, respectively. The difference between these results and the shell thickness of 0.90 μm derived from confocal laser scanning microscopy was explained by the limited resolution of about 180 nm for this technique, compared with 40-nm resolution for X-rays. Closer inspection of the shells revealed further details (Fig. 2c). The increase of the shell thickness is correlated with the appearance of a fuzzy contour around the polymeric shell and the loss of air content. Degradation of the polymeric microballoons upon aging leads to leakage of the gas filling and is associated with an increase of the shell thickness. The appearance of a fuzzy contour around the polymeric shell of the corrupted microballoons is presumably the result of the partial destruction of the polymeric network, but further investigations are needed to reveal the degradation mechanism definitively. The X-ray microscopy results directly showed that the particular micro-balloon system investigated has remarkably high stability. These balloons are able to contain gases for six months, which makes them well suited to biomedical applications. As complex materials often have three-dimensional (3D) morphologies, a number of new methods have been developed recently to perform 3D chemical mapping26–28 or 3D morphological mapping of thick, frozen biological samples29. However, of these methods, only NEXAFS tomography has high spectroscopic resolution and sensitivity, and the ability to analyse wet specimens28. To illustrate the present state of the art (achieved with a STXM), the 3D chemical composition of structured, hollow latex spheres in an aqueous solution is presented in Fig. 2d. A NEXAFS feature of the acrylate component just below the onset of the oxygen 1s edge of water was used to provide selective contrast between the acrylate, the styrene and water, and each component could be selectively mapped in 3D. As there is no inefficient X-ray optics between the sample and the detector in a STXM, the dose used to acquire the STXM tomographs was only ~200 MGy, which is considerably lower than the dose required for TXM tomography (typically 1–10 GGy). Even so, tomography is a relatively high-dose method and the ultimate spatial resolution might be limited by damage. Unfortunately, cryogenic methods only prevent mass loss and the spectroscopic changes due to chemical damage are essentially unmitigated by cryogenic techniques30. Other studies of hydrated soft matter include the in situ, real-space determination of the charge state in stimulus-responsive microgels31, the determination of crosslink density in super-absorbent polymers32, density determinations of polyelectrolyte assemblies33,34 and the correlation of metal distributions in organic biofilms35,36. The studies of microgels, crosslink density in super-absorbent polymers, and biofilms made explicit use of NEXAFS spectral differences and features, whereas the studies of the polyelectrolyte assemblies relied primarily on the ‘water-window contrast’ (at fixed photon energy) due to the elemental differences in the cross-sections of carbon and oxygen. organic electronic materials Owing to their processability from solvents, organic electronic materials may yield cheap light-emitting diodes and photovoltaic devices. Furthermore, flexible devices can be constructed. Organic devices are thus extensively studied by a large number of research groups around the world. Generally, devices are composed of donor and acceptor materials that are used in layered thin-film geometries that often include one or more buffer layers and the electrodes. a c 2 µm A B C 1 µm 1 µm 1 µm A B C 400 nm –3 –2 –1 0 1 2 3 Distance (µm) A B C Transmittance b d Figure 2 | NeXaFS imaging of latex particles and microballoons dispersed in water. a, STXM transmission image of microballoons recorded at 520 eV, that is, below the oxygen absorption edge. b, Radial transmittance profiles of micro-balloons A, B and C, labelled as in a. c, Expanded views of microballoon shells. d, Three-dimensional representations of the polyacrylate (green) and polystyrene (greyscale) distributions of water-suspended latex particles. Figures reproduced with permission from: a-c, ref. 25 © 2008 RSC; d, ref. 28 © 2007 IUCr. nmat_2399_APR09.indd 283 13/3/09 11:54:37 © 2009 Macmillan Publishers Limited. All rights reserved
REVIEW ARTICLES INSIGHT NATURE MATERIALS DOL:10.1038/NMAT2399 (typically less than 10 nm),efficient photovoltaic devices require an 50 nm intimately mixed morphology with phase separation on the scale of 10 nm,yet at the same time have a bi-continuous network or perco- lation pathways for efficient charge collection. 0 nm Mixtures of the donor polymer poly(9,9'-dioctylfluorene-co- % 11 PFB:F88T bis-N,N-(4,butylphenyl)-bis-N,N'-phenyl-1,4-phenylene-diamine) 50 50 nm (PFB)with the acceptor polymer poly(9,9'-dioctylfluorene-co- benzothiadiazole)(F8BT)have been used as an all-polymer model system for the study of morphology effects4 and charge generation 0 nm and transport dynamics".Blends of PFB and F8BT spin-cast from a low-boiling-point solvent,such as chloroform,show asmooth surface topography".Films spin-cast from a high-boiling-point solvent,such 15nm as xylene,show a more complicated morphology and surface topog- raphy characterized by micrometre-size domains".Understanding the charge generation mechanism within these domains requires 60 mapping the composition of these blend structures.Although an 1:5 PFB:F8 array of advanced techniques has been used to probe the chemistry F8BT percentage PFB percentage Height and structure of PFB:F8BT blends,only NEXAFS microscopy has composition composition the required high chemical sensitivity and spatial resolution(<um) This capability has been exploited to characterize PFB:F8BT blends cast from xylenes and chloroform".Quantitative compositional maps of xylene-cast PFB:F8BT blends with different composition ratios are shown in Fig.3.The micrometre-scale domains contain significant proportions of both polymers.In particular,the minor- ity phases of 1:5 and 5:1 PFB:F8BT xylene-blend films can contain each polymer in a proportion up to 50%.By analysing the quantita- tive composition,the superior photovoltaic performance of the 1:5 PFB:F8BT blend over the 5:1 blend could be explained:a higher pro- portion of the area of the 1:5 PFB:F8BT film has the optimum blend composition of 60 to 80 wt%F8BT.The local composition and its distribution in 1:1 PFB:F8BT films,however,was unable to explain the lower photovoltaic performance of the 1:1 PFB:F8BT blend.This was attributed to a presumed vertical structure that is difficult to characterize at present.Overall,the lower performance of xylene- 12×103 processed films relative to chloroform-processed films could not be 1.0×10 accounted for by the local blend composition at length scales above the resolution limit of~45 nm and a nanoscale phase separation at a 283284285286287 8.0×10-4 length scale below the spatial resolution has been postulated. Similarly,compositionaland morphologicalanalysisofPFB:F8BT 6.0×10-4 blends cast from chloroform provided much insight into the nano- scale morphological evolution of these blends upon annealing" 4.0×10-4 The coarsening and evolution towards purer domains has been 20×10-4 _F8BT quantified for the more aggressively annealed films.However,the ----FBT comparison with photoluminescence data of as-cast or minimally 0. annealed samples suggested the presence of a nanomorphology that 280285290295300305310315320 was below the resolution limit of the X-ray microscope used.Char- Energy (eV) acterization of PFB:F8BT blends thus simultaneously illustrates the power of compositional imaging using NEXAFS microscopy and Figure 3 NEXAFS compositional mapping applied to two-component the need to improve the spatial resolution further.Given that the organic electronic devices that show macroscopic phase separation. complex morphology is in many cases most probably 3D in nature, Quantitative (wt%)F8BT(a,d,g)and PFB(b,e,h)composition maps optimal characterization would require NEXAFS tomography2 at and AFM images (c,f,i)of PFB-F8BT blend films of variable composition. higher spatial resolution than has been possible so far. a,b,c,1:1 PFB:F8BT;d,e,f,5:1 PFB:F8BT:g.h,i,1:5 PFB:F8BT.j,Chemical structures of both polymers and their respective NEXAFS spectra,which Biofibres provide the basis of the quantitative analysis.Figure reproduced with Biofibres are some of nature's most remarkable materials.Some permission from ref.43@2007 ACS. fibres can achieve combinations of strength and toughness that are still unmatched by high-performance synthetic fibres.One of the Frequently,devices contain an active layer that is composed of fibres produced by spiders,dragline silk,is such a fibre,with an complex non-equilibrium structures of a two-component donor- unusual combination of stiffness and extensibility.Numerous mod- acceptor blend that shows phase separation on multiple length els to explain the fibres'properties exist.They are thought to be due scales,created during spin-casting and subsequent processing to alternating alanine-rich hard segments containing B-sheets and The influence of local composition and distribution on device per- glycine-rich soft segments,but the fundamental structure-property formance is of particular interest,both for light-emitting diodes* relationships in spider silk are not yet fully understood.They are and for 'bulk heterojunction technology'in photovoltaic devices4. of intrinsic scientific interest,but improved knowledge would Owing to the small exciton diffusion length in conjugated polymers also aid industrial efforts to produce biomimetic synthetic fibres. 284 NATURE MATERIALS VOL 8|APRIL 2009 www.nature.com/naturematerials 2009 Macmillan Publishers Limited.All rights reserved
284 nature materials | VOL 8 | APRIL 2009 | www.nature.com/naturematerials review articles | insight NaTure MaTerialS doi: 10.1038/nmat2399 Frequently, devices contain an active layer that is composed of complex non-equilibrium structures of a two-component donor– acceptor blend that shows phase separation on multiple length scales, created during spin-casting and subsequent processing37,38. The influence of local composition and distribution on device performance is of particular interest, both for light-emitting diodes39 and for ‘bulk heterojunction technology’ in photovoltaic devices40. Owing to the small exciton diffusion length in conjugated polymers (typically less than 10 nm), efficient photovoltaic devices require an intimately mixed morphology with phase separation on the scale of 10 nm, yet at the same time have a bi-continuous network or percolation pathways for efficient charge collection. Mixtures of the donor polymer poly(9,9′-dioctylfluorene-cobis-N,N′-(4,butylphenyl)-bis-N,N′-phenyl-1,4-phenylene-diamine) (PFB) with the acceptor polymer poly(9,9′-dioctylfluorene-cobenzothiadiazole) (F8BT) have been used as an all-polymer model system for the study of morphology effects41 and charge generation and transport dynamics42. Blends of PFB and F8BT spin-cast from a low-boiling-point solvent, such as chloroform, show a smooth surface topography41. Films spin-cast from a high-boiling-point solvent, such as xylene, show a more complicated morphology and surface topography characterized by micrometre-size domains41. Understanding the charge generation mechanism within these domains requires mapping the composition of these blend structures. Although an array of advanced techniques has been used to probe the chemistry and structure of PFB:F8BT blends, only NEXAFS microscopy has the required high chemical sensitivity and spatial resolution (<1 μm). This capability has been exploited to characterize PFB:F8BT blends cast from xylene43 and chloroform44. Quantitative compositional maps of xylene-cast PFB:F8BT blends with different composition ratios are shown in Fig. 3. The micrometre-scale domains contain significant proportions of both polymers. In particular, the minority phases of 1:5 and 5:1 PFB:F8BT xylene-blend films can contain each polymer in a proportion up to 50%. By analysing the quantitative composition, the superior photovoltaic performance of the 1:5 PFB:F8BT blend over the 5:1 blend could be explained: a higher proportion of the area of the 1:5 PFB:F8BT film has the optimum blend composition of 60 to 80 wt% F8BT. The local composition and its distribution in 1:1 PFB:F8BT films, however, was unable to explain the lower photovoltaic performance of the 1:1 PFB:F8BT blend. This was attributed to a presumed vertical structure that is difficult to characterize at present. Overall, the lower performance of xyleneprocessed films relative to chloroform-processed films could not be accounted for by the local blend composition at length scales above the resolution limit of ~45 nm and a nanoscale phase separation at a length scale below the spatial resolution has been postulated. Similarly, compositional and morphological analysis of PFB:F8BT blends cast from chloroform provided much insight into the nanoscale morphological evolution of these blends upon annealing44. The coarsening and evolution towards purer domains has been quantified for the more aggressively annealed films. However, the comparison with photoluminescence data of as-cast or minimally annealed samples suggested the presence of a nanomorphology that was below the resolution limit of the X-ray microscope used. Characterization of PFB:F8BT blends thus simultaneously illustrates the power of compositional imaging using NEXAFS microscopy and the need to improve the spatial resolution further. Given that the complex morphology is in many cases most probably 3D in nature, optimal characterization would require NEXAFS tomography28 at higher spatial resolution than has been possible so far. biofibres Biofibres are some of nature’s most remarkable materials. Some fibres can achieve combinations of strength and toughness that are still unmatched by high-performance synthetic fibres. One of the fibres produced by spiders, dragline silk, is such a fibre, with an unusual combination of stiffness and extensibility. Numerous models to explain the fibres’ properties exist. They are thought to be due to alternating alanine-rich hard segments containing β-sheets and glycine-rich soft segments, but the fundamental structure–property relationships in spider silk are not yet fully understood. They are of intrinsic scientific interest, but improved knowledge would also aid industrial efforts to produce biomimetic synthetic fibres. Figure 3 | NeXaFS compositional mapping applied to two-component organic electronic devices that show macroscopic phase separation. Quantitative (wt%) F8BT (a, d, g) and PFB (b, e, h) composition maps and AFM images (c, f, i) of PFB–F8BT blend films of variable composition. a, b, c, 1:1 PFB:F8BT; d, e, f, 5:1 PFB:F8BT; g, h, i, 1:5 PFB:F8BT. j, Chemical structures of both polymers and their respective NEXAFS spectra, which provide the basis of the quantitative analysis. Figure reproduced with permission from ref. 43 © 2007 ACS. N S N N N n PFB F8BT [ n [ [ [ j Mass absorption coefficient (cm–2g) F8BT FBT 283 284 285 286 287 1.2 × 10–5 1.0 × 10–5 8.0 × 10–4 6.0 × 10–4 4.0 × 10–4 2.0 × 10–4 0.0 280 285 290 295 300 305 310 315 320 Energy (eV) 0 nm 15 nm 1:5 PFB:F8BT 0 nm 50 nm 0 nm 50 nm 5:1 PFB:F8BT i f c 1:1 PFB:F8BT 0 50 wt% 50 90 wt% h e b 0 wt% 100 g d a 60 100 wt% 0 wt% 100 0 50 wt% 1 um 1 um 1 um PFB percentage composition F8BT percentage Height composition nmat_2399_APR09.indd 284 13/3/09 11:54:37 © 2009 Macmillan Publishers Limited. All rights reserved
NATURE MATERIALS DOL:10.1038/NMAT2399 INSIGHT I REVIEW ARTICLES The microstructure of the silk filament is controlled in part by the technological application such as sensor technology (for example, conditions under which the fibre is spun and in part by the block giant-magnetoresistance and magnetic-tunnel-junction reading copolymer structure determined by its amino-acid sequence.The heads)and magnetic data storage devices(for example,magnetic alignment of the B-sheets and the size of the crystallites and crys- random-access memory).The X-ray magnetic circular dichroism talline regions within the fibre are thought to be important factors (XMCD)49 shown in Fig.1 can be used as a contrast mechanism responsible for the tensile strength of dragline silk.This alignment in PEEM,full-fields and scannings!X-ray microscopes and for and the fibre texture can be characterized using NEXAFS micro- magnetic investigations with coherent scatterings2.In comparison scopy and systematic quantitative maps of the orientation of the with magneto-optical Kerr microscopys,the synchrotron-based B-sheets in dragline silk of the spider Nephila clavipes have been techniques show element-specific contrast (by tuning the X-ray produced and compared with the Bombyx mori cocoon fibre s.New energy to the absorption edges of the magnetically relevant ele- discoveries that help explain why spider silk has such noteworthy ments)and lateral resolutions of~25 nm,which is an improvement mechanical properties include the observation that the previously of about one order of magnitude.Although the X-ray techniques observed skin has enhanced orientation.An apparently random cannot achieve the atomic resolution possible with the spin- distribution of more-oriented B-sheet crystallites interspersed with polarized scanning tunnelling microscopes4ss,the unique advan- amorphous regions was also observed.This type of stiff reinforce- tages of soft X-ray microscopy for studying magnetic micro-and ment within a flexible matrix is a common feature of high-strength, nanostructures are the element specificity of the XMCD contrast yet flexible,materials. mechanism and its direct correlation with local spin and orbital The properties of spider dragline silk are known to depend moments,which can even be separated by applying magneto- strongly on moisture levels,with the initial stiffness dropping by optical sum ruless6s7.In addition to using the XMCD effect for three orders of magnitude upon immersion of unsupported fibres investigation of ferromagnetic samples,linearly polarized light in in water4647.Very recent initial results on the effects of moisture on conjunction with X-ray magnetic linear dichroism has been used the microstructure of the fibre are shown in Fig.4,where we com- in X-ray microscopy for the study of antiferromagnetic systemss. pare the orientation maps of the carbonyl groups for a N.clavipes The unique contrast mechanism of NEXAFS microscopy allowed fibre in dry and wet states (Fig.4a).The order parameter used(P,) ferromagnetic domains to be correlated with antiferromagnetic is equal to 1 for perfect parallel orientation,-0.5 for perfect per- domains in a number of complex magnetic thin films.For example pendicular orientation and 0 for random orientation.The dry fibre the domains of a bilayer of 1.0 nm of platinum on 1.2 nm of cobalt shows moderately oriented domains and a homogeneous micro- on a LaFeO,(100)substrate are shown in Fig.5(ref.59).The con- structure of small domains.The influence of water strongly affects tributions of the various elements to the magnetic properties could the microstructure of the fibre,resulting in a much coarser texture be distinguished because each element has its absorption edge at a and a broader range of(P)values(Fig.4b).Both (P2)distributions different photon energy and the antiferromagnetic domains of the displayed in Fig.4b have an approximately Gaussian shape and are substrate could be clearly correlated with the cobalt-specific ferro- centred at a (P,)value of about -0.1,but the distribution is much magnetic domains above it.In effect,the element-specific NEXAFS broader for the fibre in the wet,and hence low-stiffness,state. provided layer-specific depth resolution.Similar experiments The first linear X-ray dichroic measurements on fibres revealed allowed the details of ferromagnetic-antiferromagnetic coupling the qualitative radial alignment of various functional groups in to be investigated in a number of systems. Kevlar fibres',and a quantitative comparison of the carbon 1s and As the incoming and outgoing photons are not influenced by nitrogen Is signals from different Kevlar fibre grades provided a magnetic fields,transmission X-ray microscopy allows the study of quantitative comparison of the degrees oforientation in the different magnetic properties on small length scales as a function of applied fibre grades. field;for example,local hysteresis loops and magnetization profiles of cobalt-platinum multilayers deposited on self-assembled arrays Magnetic soft X-ray microscopy of polystyrene nanospheres could be assessed on the 100-nm scale62. Magnetism in confined structurests has become an important Furthermore,XMCD is very sensitive,as was demonstrated by topic for theoretical and experimental studies as well as studying magnetic carbons a Dry 0.1 6 (000 10 Dry Wet um Wet -03 -02 -01 0.0 0.1 -0.3 P》 Figure 4 NEXAFS orientational maps for spider silk in the dry and wet states.a,Maps (3 um x 7 um)of the order parameter (P2)of N.clavipes in thin sections of dragline silk in the dry and wet states.b,(P)distribution for the maps shown in a.Figure reproduced with permission from ref.46,courtesy of A.P.Hitchcock and M.Pezolet. NATURE MATERIALS VOL 8|APRIL 2009 www.nature.com/naturematerials 285 2009 Macmillan Publishers Limited.All rights reserved
nature materials | VOL 8 | APRIL 2009 | www.nature.com/naturematerials 285 NaTure MaTerialS doi: 10.1038/nmat2399 insight | review articles The microstructure of the silk filament is controlled in part by the conditions under which the fibre is spun and in part by the block copolymer structure determined by its amino-acid sequence. The alignment of the β-sheets and the size of the crystallites and crystalline regions within the fibre are thought to be important factors responsible for the tensile strength of dragline silk. This alignment and the fibre texture can be characterized using NEXAFS microscopy and systematic quantitative maps of the orientation of the β-sheets in dragline silk of the spider Nephila clavipes have been produced and compared with the Bombyx mori cocoon fibre45. New discoveries that help explain why spider silk has such noteworthy mechanical properties include the observation that the previously observed skin has enhanced orientation. An apparently random distribution of more-oriented β-sheet crystallites interspersed with amorphous regions was also observed. This type of stiff reinforcement within a flexible matrix is a common feature of high-strength, yet flexible, materials. The properties of spider dragline silk are known to depend strongly on moisture levels, with the initial stiffness dropping by three orders of magnitude upon immersion of unsupported fibres in water46,47. Very recent initial results on the effects of moisture on the microstructure of the fibre are shown in Fig. 4, where we compare the orientation maps of the carbonyl groups for a N. clavipes fibre in dry and wet states (Fig. 4a). The order parameter used 〈P2〉 is equal to 1 for perfect parallel orientation, −0.5 for perfect perpendicular orientation and 0 for random orientation. The dry fibre shows moderately oriented domains and a homogeneous microstructure of small domains. The influence of water strongly affects the microstructure of the fibre, resulting in a much coarser texture and a broader range of 〈P2〉 values (Fig. 4b). Both 〈P2〉 distributions displayed in Fig. 4b have an approximately Gaussian shape and are centred at a 〈P2〉 value of about −0.1, but the distribution is much broader for the fibre in the wet, and hence low-stiffness, state. The first linear X-ray dichroic measurements on fibres revealed the qualitative radial alignment of various functional groups in Kevlar fibres4 , and a quantitative comparison of the carbon 1s and nitrogen 1s signals from different Kevlar fibre grades provided a quantitative comparison of the degrees of orientation in the different fibre grades19. magnetic soft X-ray microscopy Magnetism in confined structures48 has become an important topic for theoretical and experimental studies as well as technological application such as sensor technology (for example, giant-magnetoresistance and magnetic-tunnel-junction reading heads) and magnetic data storage devices (for example, magnetic random-access memory). The X-ray magnetic circular dichroism (XMCD)49 shown in Fig. 1 can be used as a contrast mechanism in PEEM5 , full-field50 and scanning51 X-ray microscopes and for magnetic investigations with coherent scattering52. In comparison with magneto-optical Kerr microscopy53, the synchrotron-based techniques show element-specific contrast (by tuning the X-ray energy to the absorption edges of the magnetically relevant elements) and lateral resolutions of ~25 nm, which is an improvement of about one order of magnitude. Although the X-ray techniques cannot achieve the atomic resolution possible with the spinpolarized scanning tunnelling microscope54,55, the unique advantages of soft X-ray microscopy for studying magnetic micro- and nanostructures are the element specificity of the XMCD contrast mechanism and its direct correlation with local spin and orbital moments, which can even be separated by applying magnetooptical sum rules56,57. In addition to using the XMCD effect for investigation of ferromagnetic samples, linearly polarized light in conjunction with X-ray magnetic linear dichroism has been used in X-ray microscopy for the study of antiferromagnetic systems58–61. The unique contrast mechanism of NEXAFS microscopy allowed ferromagnetic domains to be correlated with antiferromagnetic domains in a number of complex magnetic thin films. For example, the domains of a bilayer of 1.0 nm of platinum on 1.2 nm of cobalt on a LaFeO3(100) substrate are shown in Fig. 5 (ref. 59). The contributions of the various elements to the magnetic properties could be distinguished because each element has its absorption edge at a different photon energy and the antiferromagnetic domains of the substrate could be clearly correlated with the cobalt-specific ferromagnetic domains above it. In effect, the element-specific NEXAFS provided layer-specific depth resolution. Similar experiments allowed the details of ferromagnetic–antiferromagnetic coupling to be investigated in a number of systems60,61. As the incoming and outgoing photons are not influenced by magnetic fields, transmission X-ray microscopy allows the study of magnetic properties on small length scales as a function of applied field; for example, local hysteresis loops and magnetization profiles of cobalt–platinum multilayers deposited on self-assembled arrays of polystyrene nanospheres could be assessed on the 100-nm scale62. Furthermore, XMCD is very sensitive, as was demonstrated by studying magnetic carbon63. Dry Wet –0.3 –0.2 –0.1 0.0 0.1 P2 Fraction of pixels (×100) 10 5 0 Dry Wet 1 μm 0.1 –0.3 a b Figure 4 | NeXaFS orientational maps for spider silk in the dry and wet states. a, Maps (3 μm × 7 μm) of the order parameter 〈P2〉 of N. clavipes in thin sections of dragline silk in the dry and wet states. b, 〈P2〉 distribution for the maps shown in a. Figure reproduced with permission from ref. 46, courtesy of A.P. Hitchcock and M. Pézolet. nmat_2399_APR09.indd 285 13/3/09 11:54:38 © 2009 Macmillan Publishers Limited. All rights reserved
REVIEW ARTICLES INSIGHT NATURE MATERIALS DOL:10.1038/NMAT2399 Imaging of spin-transfer switching and domain wall motion 10APL The discovery that magnetization in submicrometre patterned ferro- magneticelements can beexcited and reversed not only using magnetic 12 ACo fields but also spin-polarized currents78 opened new possibilities and technologies called 'spin transport electronics'or 'spintronics,which LaFe0,(100) exploit the intrinsic spin of the electron and its associated magnetic moment.Related effects were extensively investigated in transport measurements.However,these give a spatially integrated signal about LaFeO,layer Co layer the magnetization.Time-resolved X-ray imaging of the spin-torque- induced magnetization switching process in nanopillars revealed that magnetization switching was observed by lateral motion of a magnetic vortex across a 110 x 180 nm2 element(Fig.6).In addi- tion,domain wall motion in nanowires has been studied by applying magnetic fields?or electrical current pulses'2.The high spatial resolu- tion allows accurate comparison with micromagnetic models. Vortex dynamics The magnetic vortex is a well-known ground-state configuration of magnetization in micrometre-and nanometre-size magnetic patterns,as such patterns can minimize their stray field energy by forming an in-plane curling magnetization,either anticlock- wise (vortex circulation,c =+1)or clockwise (c=-1).To avoid Light Medium a singularity,the magnetization in the centre of the vortex turns out- of-plane,either up (vortex polarization,p=+1)or down (p=-1), forming the vortex core,which has a radius of about 5-15 nm The vortex core has a key role in vortex dynamics.In particular, the vortex shows a fundamental gyration mode,typically in the sub- 705710715720725730 770775780785790795800 gigahertz frequency range,when excited by an in-plane magnetic field pulse or a resonant alternating magnetic field,as observed Photon energy (eV) Photon energy (eV) experimentally more than 20 years ago".According to equations of motion derived in ref.74 and applied to vortex structures in ref.75, Figure 5|Domain structures in a platinum-cobalt bilayer on an the sense of rotation of this gyrotropic magnetic vortex motion only antiferromagnetic LaFeO;substrate observed in a PEEM.a,b,The depends on the vortex polarizations:anticlockwise for p =+1 and antiferromagnetic domains (a)and the cobalt domains (b)in the same clockwise for p =-1. region of the sample.The spectra shown illustrate the origin of the intensity The vortex was studied extensively in theory,simulations and contrast in the images.Normalized intensity given in arbitrary units (a.u.). experiments and was found to be a very stable configuration.Out- Comparison of the images shows that the cobalt domains align with the of-plane magnetic fields as large as~0.5 T(refs 76,77)are needed to antiferromagnetic domains (light and dark regions inside outlined areas). switch the vortex core polarization. Figure courtesy of J.Stohr. Surprisingly,dynamic X-ray microscopy experiments"s revealed (Fig.7)that the vortex core can be toggled up and down using in- Subnanosecond time-resolved NEXAFS microscopy plane magnetic bursts of one period with a peak amplitude as low as By taking advantage of the inherent time structure of the synchro- 1.5 mT (in contrast with the 500 mT mentioned above).The physi- tron,which produces X-ray flashes about 50-70 ps in duration. cal mechanism was also explained.The vortex core reversal occurs stroboscopic magnetic studies became feasible.In this way,lateral in three steps,as derived from micromagnetic simulations?:(1) resolution of about 25 nm was combined with time resolution of excitation-induced gyration leads to a deformation of the out-of- about 100 ps.Subnanosecond time-resolved NEXAFS microscopy plane core profile (that is,a region with opposite magnetization is measurements were performed for the first time using a pump- formed near the original vortex core);(2)when the deformation probe technique at the Advanced Light Source,Lawrence Berkeley reaches full out-of-plane magnetization,a vortex-antivortex pair is National Laboratory,using full-fields and photoemission electron nucleated;(3)the antivortex quickly annihilates with the original microscopes54.Ferromagnetic micrometre-size elements were vortex,dissipating the excess energy in spin waves,leaving only the excited using a microcoil producing out-of-plane magnetic field vortex with opposite polarization. pulses perpendicular to the sample plane,or using a striplines for This vortex-antivortex model for vortex core switching has been in-plane excitation. confirmed in micromagnetic simulations by several groups and Complementary to the pump-probe technique,a spatially studied in detail,not only for excitation with magnetic fields but resolved ferromagnetic resonance technique has been developedes also with spin-polarized electrons(spin torque).It was demon- in which the sample is excited by a continuous a.c.magnetic field. strated by direct X-ray imaging that a rotating field can be used to Roughly speaking,the pump-probe technique excites all mag- switch the vortex core either 'up'or 'down'depending on the sense of netic modes of motion in the sample,whereas this complementary rotation of the external fields4.Unlike linear magnetic fields or spin- technique selectively allows observation of those modes with an polarized currents,which excite both vortex core polarizations and eigenfrequency close to the frequency of the a.c.excitation.By therefore switch the vortex core back and forth,an in-plane rotating taking advantage of the element specificity of the XMCD contrast field selectively excites only one of the polarization states-One mechanism,vortex dynamics could be separately observed in the of the future challenges of magnetic X-ray microscopy will be to permalloy (NisoFe)and cobalt layers of permalloy-copper-cobalt resolve details of vortex dynamics in space and time.Time-resolved trilayers66.A 180 phase shift was measured in the gyrotropic motion STXM imaging of spin-torque-driven vortex gyration has recently of both layers. been publisheds8. 286 NATURE MATERIALS VOL 8|APRIL 2009 www.nature.com/naturematerials 2009 Macmillan Publishers Limited.All rights reserved
286 nature materials | VOL 8 | APRIL 2009 | www.nature.com/naturematerials review articles | insight NaTure MaTerialS doi: 10.1038/nmat2399 subnanosecond time-resolved neXaFs microscopy By taking advantage of the inherent time structure of the synchrotron, which produces X-ray flashes about 50–70 ps in duration, stroboscopic magnetic studies became feasible. In this way, lateral resolution of about 25 nm was combined with time resolution of about 100 ps. Subnanosecond time-resolved NEXAFS microscopy measurements were performed for the first time using a pump– probe technique at the Advanced Light Source, Lawrence Berkeley National Laboratory, using full-field6 and photoemission electron microscopes64. Ferromagnetic micrometre-size elements were excited using a microcoil6 , producing out-of-plane magnetic field pulses perpendicular to the sample plane, or using a stripline64 for in-plane excitation. Complementary to the pump–probe technique, a spatially resolved ferromagnetic resonance technique has been developed65 in which the sample is excited by a continuous a.c. magnetic field. Roughly speaking, the pump–probe technique excites all magnetic modes of motion in the sample, whereas this complementary technique selectively allows observation of those modes with an eigenfrequency close to the frequency of the a.c. excitation. By taking advantage of the element specificity of the XMCD contrast mechanism, vortex dynamics could be separately observed in the permalloy (Ni80Fe20) and cobalt layers of permalloy–copper–cobalt trilayers66. A 180° phase shift was measured in the gyrotropic motion of both layers. imaging of spin-transfer switching and domain wall motion The discovery that magnetization in submicrometre patterned ferromagnetic elements can be excited and reversed not only using magnetic fields but also spin-polarized currents67,68 opened new possibilities and technologies called ‘spin transport electronics’ or ‘spintronics’, which exploit the intrinsic spin of the electron and its associated magnetic moment. Related effects were extensively investigated in transport measurements. However, these give a spatially integrated signal about the magnetization. Time-resolved X-ray imaging of the spin-torqueinduced magnetization switching process in nanopillars69,70 revealed that magnetization switching was observed by lateral motion of a magnetic vortex across a 110 × 180 nm² element (Fig. 6). In addition, domain wall motion in nanowires has been studied by applying magnetic fields71 or electrical current pulses72. The high spatial resolution allows accurate comparison with micromagnetic models. Vortex dynamics The magnetic vortex is a well-known ground-state configuration of magnetization in micrometre- and nanometre-size magnetic patterns, as such patterns can minimize their stray field energy by forming an in-plane curling magnetization, either anticlockwise (vortex circulation, c = +1) or clockwise (c = −1). To avoid a singularity, the magnetization in the centre of the vortex turns outof-plane, either up (vortex polarization, p = +1) or down (p = −1), forming the vortex core, which has a radius of about 5–15 nm. The vortex core has a key role in vortex dynamics. In particular, the vortex shows a fundamental gyration mode, typically in the subgigahertz frequency range, when excited by an in-plane magnetic field pulse or a resonant alternating magnetic field, as observed experimentally more than 20 years ago73. According to equations of motion derived in ref. 74 and applied to vortex structures in ref. 75, the sense of rotation of this gyrotropic magnetic vortex motion only depends on the vortex polarizations: anticlockwise for p = +1 and clockwise for p = −1. The vortex was studied extensively in theory, simulations and experiments and was found to be a very stable configuration. Outof-plane magnetic fields as large as ~0.5 T (refs 76, 77) are needed to switch the vortex core polarization. Surprisingly, dynamic X-ray microscopy experiments78 revealed (Fig. 7) that the vortex core can be toggled up and down using inplane magnetic bursts of one period with a peak amplitude as low as 1.5 mT (in contrast with the 500 mT mentioned above). The physical mechanism was also explained. The vortex core reversal occurs in three steps, as derived from micromagnetic simulations78: (1) excitation-induced gyration leads to a deformation of the out-ofplane core profile (that is, a region with opposite magnetization is formed near the original vortex core); (2) when the deformation reaches full out-of-plane magnetization, a vortex–antivortex pair is nucleated; (3) the antivortex quickly annihilates with the original vortex, dissipating the excess energy in spin waves, leaving only the vortex with opposite polarization. This vortex–antivortex model for vortex core switching has been confirmed in micromagnetic simulations by several groups and studied in detail79–81, not only for excitation with magnetic fields but also with spin-polarized electrons (spin torque)82,83. It was demonstrated by direct X-ray imaging that a rotating field can be used to switch the vortex core either ‘up’ or ‘down’ depending on the sense of rotation of the external field84. Unlike linear magnetic fields or spinpolarized currents, which excite both vortex core polarizations and therefore switch the vortex core back and forth, an in-plane rotating field selectively excites only one of the polarization states85–87. One of the future challenges of magnetic X-ray microscopy will be to resolve details of vortex dynamics in space and time. Time-resolved STXM imaging of spin-torque-driven vortex gyration has recently been published88. a b Co layer 10 ÅPt 12 ÅCo LaFeO3(100) LaFeO3 layer 705 710 715 720 725 730 770 775 780 785 790 795 800 Normalized intensity (a.u.) Normalized intensity (a.u.) Dark Dark Light Light 2 μm Medium Photon energy (eV) Photon energy (eV) Figure 5 | Domain structures in a platinum–cobalt bilayer on an antiferromagnetic laFeO3 substrate observed in a PeeM. a,b,The antiferromagnetic domains (a) and the cobalt domains (b) in the same region of the sample. The spectra shown illustrate the origin of the intensity contrast in the images. Normalized intensity given in arbitrary units (a.u.). Comparison of the images shows that the cobalt domains align with the antiferromagnetic domains (light and dark regions inside outlined areas). Figure courtesy of J. Stöhr. nmat_2399_APR09.indd 286 13/3/09 11:54:39 © 2009 Macmillan Publishers Limited. All rights reserved
NATURE MATERIALS DOL:10.1038/NMAT2399 INSIGHT I REVIEW ARTICLES X-rays a:-1.00ns b:0.80ns c:1.00ns d:1.20ns e:1.40ns NME Polarizer 50 nm f:7.20ns g:8.80 ns h:9.00 ns i:9.20 ns 9.60ns Current pulses applied to the sample Detector ns X-ray pulses 1LL a:-1.00ns b:-0.40ns c:0.00 ns d:0.60ns 6 50nm e:5.60ns E7.60s g:8.00ns h:8.60ns 100nm Figure 6|Time-resolved imaging of spin-transfer switchings.a,Sketch of the experiment showing the pillar structure sandwiched between two copper contacts(shown in orange)with,from top to bottom,the investigated nanoscale magnetic element(NME;light blue),the thin copper spacer layer (orange),the ferromagnetic polarizer(blue),and additional layers (grey,blue,green)for fixing the magnetization of the polarizer.The magnetization directions are indicated by the arrows.The timing scheme is shown in the inset,where distinct colours denote pump-and-probe measurements with positive,negative or no current flowing through the sample.b,Illustration showing how the magnetization vector field (right panel)is derived from two magnetic STXM images showing the horizontal (left panel)and vertical (middle panel)magnetization as a black and white contrast of the NME (indicated by the blue circle).c,The evolution of the magnetization direction during the pulse sequence on the 110 x 180 nm2 sample.d,Same as c,but for a 110 x 150 nm2 sample.Figure reproduced with permission from refs 69,70 2006,2008 APS. Selective overview of other applications models,resulting in increased climate forcing by these aerosols than Although the general utility of NEXAFS and magnetic-dichroism previously predicted.Other examples in which characterization of microscopy may be apparent by now,it is easier to grasp the range of organic materials is frequently required are protein adsorption on possible applications by considering a few additional specific exam- biomaterials"1,environmental studies of solvated biopolymers such ples.One interesting example is the characterization of materials as various polysaccharides and proteins and the location of metal returned from the comet Wild 2 by NASA's Stardust mission.The speciess,and morphological characterization ofcomplex polymer/ organics found in the comet's materials showed a heterogeneous inorganic nanocomposites2 and unequilibrated distribution in composition.Importantly,the high spatial resolution,low damage and high chemical sensitivity Outlook and perspective of NEXAFS microscopy allowed the mapping of the composi- The development of quantitative compositional mapping of tional variations within the very small particles captured.Similarly, organic materials has already led to a wide range of applications. analysis of individual aerosol particles is important in understand- Similarly,time-resolved magnetic X-ray microscopy has made the ing their implications for global climate.The chemical composi- experimental investigation of new excitation schemes for magnetic tion of individual aerosol nanoparticles could be determined from materials possible.The X-ray microscopy user community will con- NEXAFS microscopy at high spatial resolution and the ratios of tinue to grow and extend the range of applications and capabilities total carbon to total mass and carbonyl carbon to total carbon could by improving the spatial resolution,by further increasing the infor- be mappeds.These results indicated a reaction rate for these aerosol mation content in new ways (tomography,beam-induced current particles three times lower than those typically used in climate measurements,improved time resolution and so on),by controlling NATURE MATERIALS VOL 8|APRIL 2009 www.nature.com/naturematerials 287 2009 Macmillan Publishers Limited.All rights reserved
nature materials | VOL 8 | APRIL 2009 | www.nature.com/naturematerials 287 NaTure MaTerialS doi: 10.1038/nmat2399 insight | review articles selective overview of other applications Although the general utility of NEXAFS and magnetic-dichroism microscopy may be apparent by now, it is easier to grasp the range of possible applications by considering a few additional specific examples. One interesting example is the characterization of materials returned from the comet Wild 2 by NASA’s Stardust mission89. The organics found in the comet’s materials showed a heterogeneous and unequilibrated distribution in composition. Importantly, the high spatial resolution, low damage and high chemical sensitivity of NEXAFS microscopy allowed the mapping of the compositional variations within the very small particles captured. Similarly, analysis of individual aerosol particles is important in understanding their implications for global climate. The chemical composition of individual aerosol nanoparticles could be determined from NEXAFS microscopy at high spatial resolution and the ratios of total carbon to total mass and carbonyl carbon to total carbon could be mapped90. These results indicated a reaction rate for these aerosol particles three times lower than those typically used in climate models, resulting in increased climate forcing by these aerosols than previously predicted. Other examples in which characterization of organic materials is frequently required are protein adsorption on biomaterials91, environmental studies of solvated biopolymers such as various polysaccharides and proteins and the location of metal species35,36, and morphological characterization of complex polymer/ inorganic nanocomposites92,93. outlook and perspective The development of quantitative compositional mapping of organic materials has already led to a wide range of applications. Similarly, time-resolved magnetic X-ray microscopy has made the experimental investigation of new excitation schemes for magnetic materials possible. The X-ray microscopy user community will continue to grow and extend the range of applications and capabilities by improving the spatial resolution, by further increasing the information content in new ways (tomography, beam-induced current measurements, improved time resolution and so on), by controlling a b d X-ray pulses X-rays Detector NME Polarizer 2 ns 4 ns c Current pulses applied to the sample 100 nm a b c f g h d e 50nm a: –1.00 ns b: –0.40 ns c: 0.00 ns d: 0.60 ns e: 5.60 ns f: 7.60 ns g: 8.00 ns h: 8.60 ns a b c f g h de i j 50 nm a: –1.00 ns b: 0.80 ns c: 1.00 ns d: 1.20 ns e: 1.40 ns f: 7.20 ns g: 8.80 ns h: 9.00 ns i: 9.20 ns j: 9.60 ns Figure 6 | Time-resolved imaging of spin-transfer switching69,70. a, Sketch of the experiment showing the pillar structure sandwiched between two copper contacts (shown in orange) with, from top to bottom, the investigated nanoscale magnetic element (NME; light blue), the thin copper spacer layer (orange), the ferromagnetic polarizer (blue), and additional layers (grey, blue, green) for fixing the magnetization of the polarizer. The magnetization directions are indicated by the arrows. The timing scheme is shown in the inset, where distinct colours denote pump-and-probe measurements with positive, negative or no current flowing through the sample. b, Illustration showing how the magnetization vector field (right panel) is derived from two magnetic STXM images showing the horizontal (left panel) and vertical (middle panel) magnetization as a black and white contrast of the NME (indicated by the blue circle). c, The evolution of the magnetization direction during the pulse sequence on the 110 x 180 nm2 sample. d, Same as c, but for a 110 x 150 nm2 sample. Figure reproduced with permission from refs 69,70 © 2006, 2008 APS. nmat_2399_APR09.indd 287 13/3/09 11:54:43 © 2009 Macmillan Publishers Limited. All rights reserved
REVIEW ARTICLES INSIGHT NATURE MATERIALS DOL:10.1038/NMAT2399 1.5mT 420nm M In-plane magnetic field(250 MHz) CW ACW Figure 7 Sketch of switching of the vortex core polarization by an in-plane magnetic field pulse of 1.5 mT as revealed by time-resolved X-ray microscopy"Excitation by a small in-plane alternating field (amplitude,0.1 mT)verified that switching occurred,as the sense of the gyrotropic motion,which depends only on the vortex core polarization,has changed.CW,clockwise;ACW,anticlockwise.Figure reproduced with permission from ref.78,2006 NPG. the sample environment and by making the instrumentation more diffraction pattern corresponding to high spatial resolution can be accessible.The relative simplicity and non-ultrahigh vacuum char- recovered.An improvement in spatial resolution by a factor of four acter of a STXM is particularly well suited to in situ experiments was achieved. that require control of magnetic and electric fields,pH,tempera- In contrast to lensless diffractive imaging methods,X-ray ture,solvation or gas exposure. ptychography offers to be a method generally well suited to the Regarding spatial resolution,two new approaches promise to characterization of materials,as images can be obtained in minutes solve the problem of diminishing improvements in spatial resolu- rather than hours and it offers the flexibility of being able to zoom tion over the past two decades.A two-step process interleaving the into regions of interest or to build up large fields of view of the fabrication of alternating zones promises to overcome the present specimen202.The pixellated detector required for X-ray ptycho- limitations to create small,high-aspect-ratio zones.Similarly,zone graphy could most likely be added relatively easily to most existing doubling through atomic layer deposition of high-Z materials on a and future STXMs.A complementary approach that requires com- relatively low-Z substrate template has the potential to result in very paratively simple technology yet affords high spatial resolution and high-resolution zone plates.Given these developments,zone-plate compositional information is resonant soft-X-ray scattering-s resolution for use in STXM and TXM has now reached 15 nm and is This retains the compositional sensitivity of NEXAFS by acquiring approaching 10 nm.Considerable resources and efforts of the X-ray scattering and reflectivity data sets at selected photon energies or microscopy community are also spent on new techniques and imag- over an energy range near absorption edges.The acquired informa- ing modalities other than the traditional STXM,TXM and PEEM tion can have spatial resolution as high as a few nanometres,but technologies.Coherent diffraction imaging%and 'lensless'imag- only from ensemble averages.These,however,can still be very use- ings are two such methods.The latter is a variation of previously ful as stand-alone information or in correlation with complemen- developed Fourier transform holography9.Many of these efforts tary microscopy information. are undertaken with an eye to eventual use with free-electron-laser As described,soft-X-ray microscopy is an evolving field that has facilities such as the FLASH facility at DESY,Hamburg,the LCLS at unique attributes and is expanding in a number of new and excit- the Stanford Synchrotron Radiation Laboratory,and the SCSS facility ing directions.This growth and diversification is also exemplified at Spring8,Japan,for single-pulse,femtosecond imaging00. by the increased availability of the required instrumentation.There A method that might provide the most immediate practical are now existing or planned soft X-ray microscopes at almost every improvement for actual characterization of materials is scan- synchrotron facility that operates in this energy range.In addition, ning diffraction microscopy,or X-ray ptychography.This method commercial stand-alone and laboratory-based STXM and TXM was originally developed for the scanning electron microscope. instruments are now available(for example from ACCEL Instru- In a very recent implementation with X-rays'01,diffraction pat- ments (http://www.accel.de/)and Xradia (http://www.xradia. terns were recorded in a STXM at each point along the specimen. com/)),a number of which have been delivered or ordered.The cost If the pattern is recorded to sufficiently high scattering angles,it of these instruments is comparable to a mid-range electron micro- can reveal information from features that are much smaller than scope.At the same time,rapid progress is being made in new imag- the beam size.When using diffraction patterns from overlap- ing modalities that will not only exploit existing X-ray sources,but ping spots(Fig.8),the phase problem of the reconstruction of the are explicitly geared to take advantage of the capabilities offered, diffraction pattern can be overcome and the information from the and to be offered,at existing free-electron-laser facilities and other 288 NATURE MATERIALS VOL 8|APRIL 2009 www.nature.com/naturematerials 2009 Macmillan Publishers Limited.All rights reserved
288 nature materials | VOL 8 | APRIL 2009 | www.nature.com/naturematerials review articles | insight NaTure MaTerialS doi: 10.1038/nmat2399 the sample environment and by making the instrumentation more accessible. The relative simplicity and non-ultrahigh vacuum character of a STXM is particularly well suited to in situ experiments that require control of magnetic and electric fields, pH, temperature, solvation or gas exposure. Regarding spatial resolution, two new approaches promise to solve the problem of diminishing improvements in spatial resolution over the past two decades. A two-step process interleaving the fabrication of alternating zones promises to overcome the present limitations to create small, high-aspect-ratio zones94. Similarly, zone doubling through atomic layer deposition of high-Z materials on a relatively low-Z substrate template has the potential to result in very high-resolution zone plates95. Given these developments, zone-plate resolution for use in STXM and TXM has now reached 15 nm and is approaching 10 nm. Considerable resources and efforts of the X-ray microscopy community are also spent on new techniques and imaging modalities other than the traditional STXM, TXM and PEEM technologies. Coherent diffraction imaging96 and ‘lensless’ imaging52 are two such methods. The latter is a variation of previously developed Fourier transform holography97. Many of these efforts are undertaken with an eye to eventual use with free-electron-laser facilities such as the FLASH facility at DESY, Hamburg, the LCLS at the Stanford Synchrotron Radiation Laboratory, and the SCSS facility at Spring8, Japan, for single-pulse, femtosecond imaging98–100. A method that might provide the most immediate practical improvement for actual characterization of materials is scanning diffraction microscopy, or X-ray ptychography. This method was originally developed for the scanning electron microscope. In a very recent implementation with X-rays101, diffraction patterns were recorded in a STXM at each point along the specimen. If the pattern is recorded to sufficiently high scattering angles, it can reveal information from features that are much smaller than the beam size. When using diffraction patterns from overlapping spots (Fig. 8), the phase problem of the reconstruction of the diffraction pattern can be overcome and the information from the diffraction pattern corresponding to high spatial resolution can be recovered. An improvement in spatial resolution by a factor of four was achieved. In contrast to lensless diffractive imaging methods, X-ray ptychography offers to be a method generally well suited to the characterization of materials, as images can be obtained in minutes rather than hours and it offers the flexibility of being able to zoom into regions of interest or to build up large fields of view of the specimen102. The pixellated detector required for X-ray ptychography could most likely be added relatively easily to most existing and future STXMs. A complementary approach that requires comparatively simple technology yet affords high spatial resolution and compositional information is resonant soft-X-ray scattering103–105. This retains the compositional sensitivity of NEXAFS by acquiring scattering and reflectivity data sets at selected photon energies or over an energy range near absorption edges. The acquired information can have spatial resolution as high as a few nanometres, but only from ensemble averages. These, however, can still be very useful as stand-alone information or in correlation with complementary microscopy information103. As described, soft-X-ray microscopy is an evolving field that has unique attributes and is expanding in a number of new and exciting directions. This growth and diversification is also exemplified by the increased availability of the required instrumentation. There are now existing or planned soft X-ray microscopes at almost every synchrotron facility that operates in this energy range. In addition, commercial stand-alone and laboratory-based STXM and TXM instruments are now available (for example from ACCEL Instruments (http://www.accel.de/) and Xradia (http://www.xradia. com/)), a number of which have been delivered or ordered. The cost of these instruments is comparable to a mid-range electron microscope. At the same time, rapid progress is being made in new imaging modalities that will not only exploit existing X-ray sources, but are explicitly geared to take advantage of the capabilities offered, and to be offered, at existing free-electron-laser facilities and other 420 nm 0.1 mT 1.5 mT CW ACW In-plane magnetic field (250 MHz) Figure 7 | Sketch of switching of the vortex core polarization by an in-plane magnetic field pulse of 1.5 mT as revealed by time-resolved X-ray microscopy78. Excitation by a small in-plane alternating field (amplitude, 0.1 mT) verified that switching occurred, as the sense of the gyrotropic motion, which depends only on the vortex core polarization, has changed. CW, clockwise; ACW, anticlockwise. Figure reproduced with permission from ref. 78, © 2006 NPG. nmat_2399_APR09.indd 288 13/3/09 11:54:47 © 2009 Macmillan Publishers Limited. All rights reserved
NATURE MATERIALS DOL:10.1038/NMAT2399 INSIGHT I REVIEW ARTICLES 12.Bluhm,H.et al.Soft X-ray microscopy and spectroscopy at the molecular environmental science beamline at the Advanced Light Source. J.Electron Spectrosc.Relat.Phenom.150,86-104 (2006) 13.Birrell,G.B.,Hedberg.K.K.,Habliston,D.L.Griffith,O.H.Biological applications of photoelectron imaging A practical perspective. Ultramicroscopy 36,235-251(1991). Zone-plate lens 14.Griffith,O.H.Rempfer,G.F.Photoelectron imaging in cell biology. Annu.Rev.Biophys.Biophys.Chem.14,113-130 (1985). 15.Tonner,B.Harp,G.R.Photoelectron microscopy with synchrotron radiation.Rev.Sci.Instrum.59,853-858(1988). 16.Rightor,E.G.et al.Spectromicroscopy of poly(ethylene terephthalate): Scanned specimen Comparison of spectra and radiation damage rates in X-ray absorption and electron energy loss.I.Phrys.Chem.B 101,1950-1960(1997). 17.Dhez,O.,Ade,H.Urquhart,S.Calibrated NEXAFS spectra of some common polymers.J.Electron Spectrosc.Relat.Phenom.128,85-96(2003) 18.Urquhart,S.G.Ade,H.Trends in the carbonyl core (C 1s,O 1s)c transition in the near edge X-ray absorption fine structure spectra of organic molecules.I.Phys.Chem.B 106,8531-8538(2002). 19.Smith,A.P.Ade,H.Quantitative orientational analysis of a polymeric material (Kevlar fiber)with X-ray microspectroscopy.Appl.Phys.Lett. 69,3833-3835(1996). 20.Kilcoyne,A.L D.etal Interferometer-controlled scanning transmission X-ray microscopes at the Advanced Light Source.J.Synchrotron Radiat. 10,125-136(2003). 21.Jacobsen,C.,Wirick,S.,Flynn,G.Zimba,C.Soft X-ray spectroscopy Diffraction pattern from image sequences with sub-100 nm spatial resolution.I.Microsc. 197,173-184(2000) 22.Ade,H.et al.X-ray spectromi croscopy with a zone plate generated microprobe.Appl.Phys.Lett.56,1841-1843(1990). 23.Gunther,S.,Kaulich,B.,Gregoratti,L.Kiskinova,M.Photoelectron b Transmission image With diffraction microscopy and applications in surface and materials science.Prog.Surf.Sci. 70,187-260(2002). 24.Locatelli,A.,Aballe,L.,Mentes,T.O.,Kiskinova,M.Bauer,E. Photoemission electron microscopy with chemical sensitivity:SPELEEM 88800 methods and applications.Surf.Interface Anal.38,1554-1557(2006). 25. Tzvetkov,G.et al.In situ characterization of gas-filled microballoons using soft X-ray microspectroscopy.Soft Matter 4,510-514(2008). 26.Iwata,N.et al.Chemical component mapping of pulverized toner by scanning transmission X-ray microscopy.Micron 37,290-295(2006). 27. Mobus,G.Inkson,B.J.Three-dimensional reconstruction of buried nanoparticles by element-sensitive tomography based on inelastically scattered electrons.Appl.Phys.Lett.79,1369-1371 (2001). 28.Johansson,G.A.,Tyliszczak,T..Mitchell,G.E.,Keefe,M.H. Figure 8|Illustration of X-ray ptychography.a,Image creation in a STXM Hitchcock,A.P.Three-dimensional chemical mapping by scanning with a pixellated detector.b,c,Simulated images when the angularly transmission X-ray spectromicroscopy.I.Synchrotron Radiat. resolved transmitted diffraction pattern is used (c)and total transmission 14,395-402(2007). plotted as a function of beam position(b).The circles in b and c represent 29.Weiss,D.etal Computed tomography of cryogenic biological specimens based on X-ray microscopic images.Ultramicroscopy 84,185-197(2000). the nominal spatial resolution without the diffraction enhancement.Figure 30.Beetz,T.Jacobsen,C.Soft X-ray radiation-damage studies in PMMA using reproduced with permission from ref.102 2008 AAAS a cryo-STXM.J.Synchrotron Radiat.10,280-283 (2003). 31.Fujii,S.,Armes,S.P,Araki,T.Ade,H.Direct imaging and spectroscopic characterization of stimulus-responsive microgels..Am. Chem.Soc. planned fourth-generation light sources.Given the unique contrast 127,16808-16809(2005). mechanism and time resolution,X-ray microscopy will remain a 32.Mitchell,G.E.et al.Quantitative characterization of microscopic variations in very useful characterization method for a wide range of materials. the cross-link density of gels.Macromolecules 35,1336-1341 (2002). 33.Kohler,K.eta Soft X-ray Microscopy to characterize polyelectrolyte References assemblies.I.Phys.Chem.B 111,8388-8393 (2007). 1. Stohr,I.NEXAFS Spectroscopy (Springer,1992). 34.Dejugnat,C.et al.Membrane densification of heated polyelectrolyte Stohr,&Siegmann,H.C.Magnetism(Springer,2006). multilayer capsules characterized by soft X-ray microscopy.Adv.Mater 3. Ade,H.et al.Chemical contrast in X-ray microscopy and spatially resolved 19,1331-1336(2007). XANES spectroscopy of organic specimens.Science 258,972-975(1992). 35.Dynes,J.J.et al.Speciation and quantitative mapping of metal species Ade,H.Hsiao,B.X-ray linear dichroism microscopy.Science in microbial biofilms using scanning transmission X-ray microscopy. 262,1427-1429(1993). Environ.Sci.Technol.40,1556-1565(2006). 5. Stohr,I.et al.Element-specific magnetic microscopy with circularly polarized 36.Lawrence,J.R.et al.Mapping of metal species in biofilms using X-rays.Scie1e259,658-661(1993). scanning transmission X-ray microscopy.Geochim.Cosmochim.Acta 6.Stoll,H.et al.High-resolution imaging of fast magnetization dynamics in 69,A600(2005). magnetic nanostructures.Appl.Phys.Lett.84,3328-3330(2004). 37.Halls,J.J.M.et al.Efficient photodiodes from interpenetrating polymer 7. Vogel,J.et al.Time-resolved magnetic domain imaging by X-ray networks.Nature 376,498-500(1995). photoemission electron microscopy.Appl Phys.Lett.82,2299-2301(2003). 38.Yu,G.,Gao,J,Hummelen,J.C..Wudl,E.Heeger,A.J.Polymer photovoltaic 8. Schmahl,G.,Rudolph,D.,Niemann,B.Christ,O.Zone-plate X-ray cells-Enhanced efficiencies via a network of internal donor-acceptor microscopy.Q.Rev.Biophys.13,297-315(1980) heterojunctions.Science 270,1789-1791(1995). 9 Kirz,J.,Jacobsen,C.Howells,M.Soft X-ray microscopes and their 39.McNeill,C.R.et al.Nanoscale quantitative chemical mapping of conjugated biological applications.Q.Rev.Biophys.28,33-130(1995). polymer blends.Nano Lett.6,1202-1206(2006). 10.Schneider,G.Cryo X-ray microscopy with high spatial resolution in 40. Hoppe,H.&Sariciftci,N.S.Morphology of polymer/fullerene bulk amplitude and phase contrast.Ultramicroscopy 75,85-104(1998). heterojunction solar cells.J.Mater.Chem.16,45-61(2006). 11.Ade,H.Hitchcock,A.P.NEXAFS microscopy,resonant scattering and 41.Arias,A.C.et al.Photovoltaic performance and morphology of polyfluorene resonant reflectivity:composition and orientation probed in real and blends:A combined microscopic and photovoltaic investigation reciprocal space.Polymer 49,643-675 (2008). Macromolecules 34,6005-6013 (2001). NATURE MATERIALS VOL 8|APRIL 2009 www.nature.com/naturematerials 289 2009 Macmillan Publishers Limited.All rights reserved
nature materials | VOL 8 | APRIL 2009 | www.nature.com/naturematerials 289 NaTure MaTerialS doi: 10.1038/nmat2399 insight | review articles planned fourth-generation light sources. Given the unique contrast mechanism and time resolution, X-ray microscopy will remain a very useful characterization method for a wide range of materials. references 1. Stöhr, J. NEXAFS Spectroscopy (Springer, 1992). 2. Stöhr, J. & Siegmann, H. C. Magnetism (Springer, 2006). 3. Ade, H. et al. Chemical contrast in X-ray microscopy and spatially resolved XANES spectroscopy of organic specimens. Science 258, 972–975 (1992). 4. Ade, H. & Hsiao, B. X-ray linear dichroism microscopy. Science 262, 1427–1429 (1993). 5. Stöhr, J. et al. Element-specific magnetic microscopy with circularly polarized X-rays. Science 259, 658–661 (1993). 6. Stoll, H. et al. High-resolution imaging of fast magnetization dynamics in magnetic nanostructures. Appl. Phys. Lett. 84, 3328–3330 (2004). 7. Vogel, J. et al. Time-resolved magnetic domain imaging by X-ray photoemission electron microscopy. Appl. Phys. Lett. 82, 2299–2301 (2003). 8. Schmahl, G., Rudolph, D., Niemann, B. & Christ, O. Zone-plate X-ray microscopy. Q. Rev. Biophys. 13, 297–315 (1980). 9. Kirz, J., Jacobsen, C. & Howells, M. Soft X-ray microscopes and their biological applications. Q. Rev. Biophys. 28, 33–130 (1995). 10. Schneider, G. Cryo X-ray microscopy with high spatial resolution in amplitude and phase contrast. Ultramicroscopy 75, 85–104 (1998). 11. Ade, H. & Hitchcock, A. P. NEXAFS microscopy, resonant scattering and resonant reflectivity: composition and orientation probed in real and reciprocal space. Polymer 49, 643–675 (2008). 12. Bluhm, H. et al. Soft X-ray microscopy and spectroscopy at the molecular environmental science beamline at the Advanced Light Source. J. Electron Spectrosc. Relat. Phenom. 150, 86–104 (2006). 13. Birrell, G. B., Hedberg, K. K., Habliston, D. L. & Griffith, O. H. Biological applications of photoelectron imaging: A practical perspective. Ultramicroscopy 36, 235–251 (1991). 14. Griffith, O. H. & Rempfer, G. F. Photoelectron imaging in cell biology. Annu. Rev. Biophys. Biophys. Chem. 14, 113–130 (1985). 15. Tonner, B. & Harp, G. R. Photoelectron microscopy with synchrotron radiation. Rev. Sci. Instrum. 59, 853–858 (1988). 16. Rightor, E. G. et al. Spectromicroscopy of poly(ethylene terephthalate): Comparison of spectra and radiation damage rates in X-ray absorption and electron energy loss. J. Phys. Chem. B 101, 1950–1960 (1997). 17. Dhez, O., Ade, H. & Urquhart, S. Calibrated NEXAFS spectra of some common polymers. J. Electron Spectrosc. Relat. Phenom. 128, 85–96 (2003). 18. Urquhart, S. G. & Ade, H. Trends in the carbonyl core (C 1s, O 1s) → π*C=O transition in the near edge X-ray absorption fine structure spectra of organic molecules. J. Phys. Chem. B 106, 8531–8538 (2002). 19. Smith, A. P. & Ade, H. Quantitative orientational analysis of a polymeric material (Kevlar fiber) with X-ray microspectroscopy. Appl. Phys. Lett. 69, 3833–3835 (1996). 20. Kilcoyne, A. L. D. et al. Interferometer-controlled scanning transmission X-ray microscopes at the Advanced Light Source. J. Synchrotron Radiat. 10, 125–136 (2003). 21. Jacobsen, C., Wirick, S., Flynn, G. & Zimba, C. Soft X-ray spectroscopy from image sequences with sub-100 nm spatial resolution. J. Microsc. 197, 173–184 (2000). 22. Ade, H. et al. X-ray spectromicroscopy with a zone plate generated microprobe. Appl. Phys. Lett. 56, 1841–1843 (1990). 23. Gunther, S., Kaulich, B., Gregoratti, L. & Kiskinova, M. Photoelectron microscopy and applications in surface and materials science. Prog. Surf. Sci. 70, 187–260 (2002). 24. Locatelli, A., Aballe, L., Mentes, T. O., Kiskinova, M. & Bauer, E. Photoemission electron microscopy with chemical sensitivity: SPELEEM methods and applications. Surf. Interface Anal. 38, 1554–1557 (2006). 25. Tzvetkov, G. et al. In situ characterization of gas-filled microballoons using soft X-ray microspectroscopy. Soft Matter 4, 510–514 (2008). 26. Iwata, N. et al. Chemical component mapping of pulverized toner by scanning transmission X-ray microscopy. Micron 37, 290–295 (2006). 27. Mobus, G. & Inkson, B. J. Three-dimensional reconstruction of buried nanoparticles by element-sensitive tomography based on inelastically scattered electrons. Appl. Phys. Lett. 79, 1369–1371 (2001). 28. Johansson, G. A., Tyliszczak, T., Mitchell, G. E., Keefe, M. H. & Hitchcock, A. P. Three-dimensional chemical mapping by scanning transmission X-ray spectromicroscopy. J. Synchrotron Radiat. 14, 395–402 (2007). 29. Weiss, D. et al. Computed tomography of cryogenic biological specimens based on X-ray microscopic images. Ultramicroscopy 84, 185–197 (2000). 30. Beetz, T. & Jacobsen, C. Soft X-ray radiation-damage studies in PMMA using a cryo-STXM. J. Synchrotron Radiat. 10, 280–283 (2003). 31. Fujii, S., Armes, S. P., Araki, T. & Ade, H. Direct imaging and spectroscopic characterization of stimulus-responsive microgels. J. Am. Chem. Soc. 127, 16808–16809 (2005). 32. Mitchell, G. E. et al. Quantitative characterization of microscopic variations in the cross-link density of gels. Macromolecules 35, 1336–1341 (2002). 33. Köhler, K. et al. Soft X-ray Microscopy to characterize polyelectrolyte assemblies. J. Phys. Chem. B 111, 8388–8393 (2007). 34. Déjugnat, C. et al. Membrane densification of heated polyelectrolyte multilayer capsules characterized by soft X-ray microscopy. Adv. Mater. 19, 1331–1336 (2007). 35. Dynes, J. J. et al. Speciation and quantitative mapping of metal species in microbial biofilms using scanning transmission X-ray microscopy. Environ. Sci. Technol. 40, 1556–1565 (2006). 36. Lawrence, J. R. et al. Mapping of metal species in biofilms using scanning transmission X-ray microscopy. Geochim. Cosmochim. Acta 69, A600 (2005). 37. Halls, J. J. M. et al. Efficient photodiodes from interpenetrating polymer networks. Nature 376, 498–500 (1995). 38. Yu, G., Gao, J., Hummelen, J. C., Wudl, F. & Heeger, A. J. Polymer photovoltaic cells - Enhanced efficiencies via a network of internal donor-acceptor heterojunctions. Science 270, 1789–1791 (1995). 39. McNeill, C. R. et al. Nanoscale quantitative chemical mapping of conjugated polymer blends. Nano Lett. 6, 1202–1206 (2006). 40. Hoppe, H. & Sariciftci, N. S. Morphology of polymer/fullerene bulk heterojunction solar cells. J. Mater. Chem. 16, 45–61 (2006). 41. Arias, A. C. et al. Photovoltaic performance and morphology of polyfluorene blends: A combined microscopic and photovoltaic investigation. Macromolecules 34, 6005–6013 (2001). Transmission image Diffraction pattern Scanned specimen Zone-plate lens With diffraction a b c Figure 8 | illustration of X-ray ptychography. a, Image creation in a STXM with a pixellated detector. b,c, Simulated images when the angularly resolved transmitted diffraction pattern is used (c) and total transmission plotted as a function of beam position (b). The circles in b and c represent the nominal spatial resolution without the diffraction enhancement. Figure reproduced with permission from ref. 102 © 2008 AAAS nmat_2399_APR09.indd 289 13/3/09 11:54:49 © 2009 Macmillan Publishers Limited. All rights reserved
REVIEW ARTICLES IINSIGHT NATURE MATERIALS DOL:10.1038/NMAT2399 42.Morteani,A.C.,Sreearunothai,P,Herz,L.M.,Friend,R.H.Silva,C 76.Okuno,T..Shigeto,K.,Ono,T.,Mibu,K.Shinjo,T.MFM study of Exciton regeneration at polymeric semiconductor heterojunctions. magnetic vortex cores in circular permalloy dots:behavior in external field. Phys.Rev.Lett..92,247402(2004). J.Magn.Magn.Mater.240,1-6 (2002). 43.MeNeill,C.R.et al X-ray microscopy of photovoltaic polyfluorene blends: 77.Thiaville,A.,Garcia,J.M.,Dittrich,R.,Miltat,J.Schrefl,T.Micromagnetic Relating the nanomorphology to device performance.Macromolecules study of Bloch-point-mediated vortex core reversal.Phys.Rev.B 40.3263-3270(2007). 67,094410(2003). 44.MeNeill,C.R.et al.Evolution of the nanomorphology of photovoltaic 78.Van Waeyenberge,B.et al.Magnetic vortex core reversal by excitation with polyfluorene blends:Sub-100 nm resolution with X-ray spectromicroscopy short bursts of an alternating field.Nature 444,461-464 (2006). Nanotechnology 19,424015(2008). 79.Xiao,Q.E,Rudge,J.,Choi,B.C..Hong.Y.K.Donohoe,G.Dynamics of vortex 45.Rousseau,M.E.,Hernandez Cruz,D.,West,M.M.,Hitchcock,A.P.& core switching in ferromagnetic nanodisks.Appl.Phys.Lett.89,262507(2006). Pezolet,M.Nephila clavipes spider dragline silk microstructure 80.Hertel,R.,Gliga,S.,Fahnle,M.Schneider,C.M.Ultrafast nanomagnetic studied by scanning transmission X-ray microscopy.I.Am.Chem.Soc. toggle switching of vortex cores.Phrys.Rev.Lett.98,117201 (2007). 129,3897-3905(2007). 81.Lee,K.S.,Guslienko,K.Y.,Lee,J.Y.Kim,S.K.Ultrafast vortex-core 46.Pezolet,M.et al.Mapping Protein Orientation in Spider Silk by STXM- reversal dynamics in ferromagnetic nanodots.Phys.Rev.B 76,174410(2007) The Effect of Water.2007 Activity Report,118-119 (Canadian Light 82.Yamada,K.et al.Electrical switching of the vortex core in a magnetic disk. Source,2007). Nature Mater.6,269-273(2007). 47.Gosline,J.M.Guerette,P.AOrtlepp,C.S.&Savage,K.N.The mechanical 83.Kim,S.K.,Choi,Y.S.,Lee,K.S.,Guslienko,K.Y.Jeong,D.E. design of spider silks:From fibroin sequence to mechanical function. Electric-current-driven vortex-core reversal in soft magnetic nanodots. 1.Exp.Bi0l.202,3295-3303(1999) Appl.Phys.Lett.91,082506(2007) 48.Bader,S.D.Magnetism in low dimensionality.Surf.Sci.500,172-188(2002) 84.Curcic,M.et al.Polarisation selective magnetic vortex dynamics and core 49.Schutz,G.et al.Absorption of circularly polarized X-Rays in iron. reversal in rotating magnetic fields.Phys.Rev.Lett.101,197204 (2008). Ps.Rev.Let.58,737-740(1987). 85.Zagorodny,J.P.,Gaididei,Y.,Mertens,E.G.Bishop,A.R.Switching 50.Fischer,P.et al.Imaging of magnetic domains by transmission X-ray of vortex polarization in 2D easy-plane magnets by magnetic fields. microscopy.I.Phys.D 31,649-655(1998). E1 r.Phys.1B31,471-487(2003). 51.Warwick,T.et al.A scanning transmission X-ray microscope for materials 86.Kravchuk,V.P..Sheka,D.D.,Gaididei,Y.Mertens,E.G.Controlled vortex science spectromicroscopy at the Advanced Light Source.Rev.Sci.Instrum. core switching in a magnetic nanodisk by a rotating field.I.Appl.Phys. 69,2964-2973(1998). 102,043908(2007). 52.Eisebitt,S.et al.Lensless imaging of magnetic nanostructures by X-ray 87.Kim,S.K.,Lee,K.S.,Yu,Y.S.Choi,Y.S.Reliable low-power control of spectro-holography.Nature 432,885-888(2004). ultrafast vortex-core switching with the selectivity in an array of vortex states 53.Hubert,A.Schafer,R.Magnetic Domains-The Analysis of Magnetic by in-plane circular-rotational magnetic fields and spin-polarized currents. Microstructures(Springer,1998). Appl.Phys.Lett.92,022509(2008). 54.Bode,M.Spin-polarized scanning tunnelling microscopy.Rep.Prog.Phys 88.Bolte,M.et al.Time-resolved X-ray microscopy of spin-torque-induced 66.523-582(2003). magnetic vortex gyration.Phys.Rev.Lett.100,176601 (2008). 55.Wachowiak,A.et al.Direct observation of internal spin structure of magnetic 89.Sandford,S.A.et al.Organics captured from comet 81P/Wild 2 by the vortex cores.Science 298,577-580(2002). Stardust spacecraft.Science 314,1720-1724(2006). 56.Carra,P,Thole,B.T.,Altarelli,M.Wang,X.D.X-ray circular-dichroism 90.Maria,S.E,Russell,L.M.,Gilles,M.K.Myneni,S.C.B.Organic aerosol and local magnetic-fields.Phys.Rev.Lett.70,694-697(1993). growth mechanisms and their climate-forcing implications.Science 57.Thole,B.T.Carra,P..Sette,&Van der Laan,G.X-ray circular-dichroism as 306,1921-1924(2004). a probe of orbital magnetization.Phys.Rev.Lett.68,1943-1946(1992). 91.Li,L et al X-ray microscopy studies of protein adsorption on a phase 58.Scholl,A.et al.Observation of antiferromagnetic domains in epitaxial thin segregated polystyrene/polymethylmethacrylate surface.2.Effect of pH on site 6lms.Science287,1014-1016(2000). preference.J.Phys.Chem.B 112,2150-2158(2008). 59.Nolting,F.et al.Direct observation of the alignment of ferromagnetic spins by 92.Si,M.et al.Compatibilizing bulk polymer blends by using organoclays antiferromagnetic spins.Nature 405,767-769(2000) Macromolecules 39,4793-4801(2006). 60.Ohldag.H.et al.Spectroscopic identification and direct imaging of interfacial 93.Zhang.W.H.et al.Effect of methyl methacrylate/polyhedral oligomeric magnetic spins.Phrys.Rev.Lett.87,247201 (2001). silsesquioxane random copolymers in compatibilization of polystyrene 61.Hillebrecht,F.U.et al.Magnetic moments at the surface of antiferromagnetic and poly(methyl methacrylate)blends.Macromolecules3,8029-8038(2002). NiO(100).Phys.Rev.Let.86,3419-3422(2001) 94.Chao,W.L,Harteneck,B.D.,Liddle,J.A.,Anderson,E.H.&Attwood,D.T. 62.Eimuller,T.et al.Spin-reorientation transition in Co/Pt multilayers on Soft X-ray microscopy at a spatial resolution better than 15 nm.Nature nanospheres.Phys.Rev.B 77,134415(2008). 435,1210-1213(2005). 63.Ohldag.H.et al pi-Electron ferromagnetism in metal-free carbon probed by 95.Jefimovs,K.et al Zone-doubling technique to produce ultrahigh-resolution soft X-ray dichroism.Phys.Rev.Lett.98,187204(2007). x-ray optics.Phys.Rev.Lett.99,264801 (2007). 64.Choe,S.B.et al.Vortex core-driven magnetization dynamics.Science 96.Miao,J.W.,Charalambous,P.,Kirz,J.Sayre,D.Extending the methodology 304,420-422(2004). of X-ray crystallography to allow imaging of micrometre-sized non-crystalline 65.Puzic,A.et al Spatially resolved ferromagnetic resonance:Imaging of specimens.Nature 400,342-344(1999). ferromagnetic eigenmodes.J.Appl.Phys.97,10E704(2005). 97.McNulty,I.,Kirz,I.Jacobsen,C.High resolution imaging by Fourier 66.Chou,K.W.et al.Vortex dynamics in coupled ferromagnetic multilayer transform X-ray holography.Science 256,1009-1012(1992). structures.J.Appl.Phys.99,08F305(2006). 98.Neutze,R,Wouts,R.,van der Spoel,D.,Weckert,E.Hajdu,J.Potential 67.Slonczewski,J.C.Current-driven excitation of magnetic multilayers. for biomolecular imaging with femtosecond X-ray pulses.Nature J.Magn.Magn.Mater.159,L1-L7 (1996). 406,752-757(2000) 68.Berger,L.Emission of spin waves by a magnetic multilayer traversed by a 99.Chapman,H.N.et al.Femtosecond diffractive imaging with a soft-X-ray current.Ph5.ReB54,9353-9358(1996). free-electron laser.Nature Phys.2,839-843(2006). 69.Acremann,Y.et al.Time-resolved imaging of spin transfer switching:Beyond 100.Feldhaus,J.,Arthur,J.Hastings,J.B.X-ray free-electron lasers.I.Phys.B the macrospin concept.Phys.Rev.Lett.96,217202(2006). 38.S799-S819(2005). 70.Strachan,I.P.et al.Direct observation of spin-torque driven 101.Thibault,P.et al.High-resolution scanning X-ray diffraction microscopy. magnetization reversal through nonuniform modes.Phys.Rev.Lett Science321,379-382(2008) 100,247201(2008). 102.Chapman,H.N.Focus on X-ray diffraction.Science 321,352-353(2008). 71.Bryan,M.T.,Fry,P.W.,Fischer,P.I.Allwood,D.A.Observation of 103.Araki,T.et al.Soft X-ray resonant scattering of structured polymer field-induced domain wall propagation in magnetic nanowires by magnetic nanoparticles.Appl.Phys.Lett.89,124106(2006) transmission X-ray microscopy.J.Appl Phys.103,07D909(2008). 104.Wang.C.,Araki,T.Ade,H.Soft X-ray resonant reflectivity of low Z material 72.Meier,G.et al.Direct imaging of stochastic domain-wall motion driven by thin films.Appl.Phys.Lett.87,214109 (2005) nanosecond current pulses.Phys.Rev.Lett.98,187202(2007). 105.Wang.C.et al.Resonant soft X-ray reflectivity of organic thin films: 73.Argyle,B.E.,Terrenzio,E.&Slonczewski,J.C.Magnetic vortex Capabilities and limitations.I.Vac.Sci.Technol.A 25,575-586(2007). dynamics using the optical Cotton-Mouton effect.Phys.Rev.Lett. 53,190-193(1984). Acknowledgements 74.Thiele,A.A.Steady-state motion of magnetic domains.Phys.Rev.Lett. We are grateful to J.Stohr,R.Fink,A.P.Hitchcock,M.Pezolet,C.MeNeill, 30、230-233(1973). Y.Acremann and H.Chapman for providing us with figures and A.P.Hitchcock 75.Huber,D.L Equation of motion of a spin vortex in a two-dimensional planar for commenting on a draft document.H.A.is supported by the US Department of magnet.L.Appl.Phys.53,1899-1900(1982). Energy under contract DE-FG02-98ER45737. 290 NATURE MATERIALS VOL 8 APRIL 2009 www.nature.com/naturematerials 2009 Macmillan Publishers Limited.All rights reserved
290 nature materials | VOL 8 | APRIL 2009 | www.nature.com/naturematerials review articles | insight NaTure MaTerialS doi: 10.1038/nmat2399 42. Morteani, A. C., Sreearunothai, P., Herz, L. M., Friend, R. H. & Silva, C. Exciton regeneration at polymeric semiconductor heterojunctions. Phys. Rev. Lett. 92, 247402 (2004). 43. McNeill, C. R. et al. X-ray microscopy of photovoltaic polyfluorene blends: Relating the nanomorphology to device performance. Macromolecules 40, 3263–3270 (2007). 44. McNeill, C. R. et al. Evolution of the nanomorphology of photovoltaic polyfluorene blends: Sub-100 nm resolution with X-ray spectromicroscopy. Nanotechnology 19, 424015 (2008). 45. Rousseau, M. E., Hernández Cruz, D., West, M. M., Hitchcock, A. P. & Pezolet, M. Nephila clavipes spider dragline silk microstructure studied by scanning transmission X-ray microscopy. J. Am. Chem. Soc. 129, 3897–3905 (2007). 46. Pézolet, M. et al. Mapping Protein Orientation in Spider Silk by STXM — The Effect of Water. 2007 Activity Report, 118–119 (Canadian Light Source, 2007). 47. Gosline, J. M., Guerette, P. A., Ortlepp, C. S. & Savage, K. N. The mechanical design of spider silks: From fibroin sequence to mechanical function. J. Exp. Biol. 202, 3295–3303 (1999). 48. Bader, S. D. Magnetism in low dimensionality. Surf. Sci. 500, 172–188 (2002). 49. Schütz, G. et al. Absorption of circularly polarized X-Rays in iron. Phys. Rev. Lett. 58, 737–740 (1987). 50. Fischer, P. et al. Imaging of magnetic domains by transmission X-ray microscopy. J. Phys. D 31, 649–655 (1998). 51. Warwick, T. et al. A scanning transmission X-ray microscope for materials science spectromicroscopy at the Advanced Light Source. Rev. Sci. Instrum. 69, 2964–2973 (1998). 52. Eisebitt, S. et al. Lensless imaging of magnetic nanostructures by X-ray spectro-holography. Nature 432, 885–888 (2004). 53. Hubert, A. & Schäfer, R. Magnetic Domains — The Analysis of Magnetic Microstructures (Springer, 1998). 54. Bode, M. Spin-polarized scanning tunnelling microscopy. Rep. Prog. Phys. 66, 523–582 (2003). 55. Wachowiak, A. et al. Direct observation of internal spin structure of magnetic vortex cores. Science 298, 577–580 (2002). 56. Carra, P., Thole, B. T., Altarelli, M. & Wang, X. D. X-ray circular-dichroism and local magnetic-fields. Phys. Rev. Lett. 70, 694–697 (1993). 57. Thole, B. T., Carra, P., Sette, F. & Van der Laan, G. X-ray circular-dichroism as a probe of orbital magnetization. Phys. Rev. Lett. 68, 1943–1946 (1992). 58. Scholl, A. et al. Observation of antiferromagnetic domains in epitaxial thin films. Science 287, 1014–1016 (2000). 59. Nolting, F. et al. Direct observation of the alignment of ferromagnetic spins by antiferromagnetic spins. Nature 405, 767–769 (2000). 60. Ohldag, H. et al. Spectroscopic identification and direct imaging of interfacial magnetic spins. Phys. Rev. Lett. 87, 247201 (2001). 61. Hillebrecht, F. U. et al. Magnetic moments at the surface of antiferromagnetic NiO(100). Phys. Rev. Lett. 86, 3419–3422 (2001). 62. Eimüller, T. et al. Spin-reorientation transition in Co/Pt multilayers on nanospheres. Phys. Rev. B 77, 134415 (2008). 63. Ohldag, H. et al. pi-Electron ferromagnetism in metal-free carbon probed by soft X-ray dichroism. Phys. Rev. Lett. 98, 187204 (2007). 64. Choe, S. B. et al. Vortex core-driven magnetization dynamics. Science 304, 420–422 (2004). 65. Puzic, A. et al. Spatially resolved ferromagnetic resonance: Imaging of ferromagnetic eigenmodes. J. Appl. Phys. 97, 10E704 (2005). 66. Chou, K. W. et al. Vortex dynamics in coupled ferromagnetic multilayer structures. J. Appl. Phys. 99, 08F305 (2006). 67. Slonczewski, J. C. Current-driven excitation of magnetic multilayers. J. Magn. Magn. Mater. 159, L1–L7 (1996). 68. Berger, L. Emission of spin waves by a magnetic multilayer traversed by a current. Phys. Rev. B 54, 9353–9358 (1996). 69. Acremann, Y. et al. Time-resolved imaging of spin transfer switching: Beyond the macrospin concept. Phys. Rev. Lett. 96, 217202 (2006). 70. Strachan, J. P. et al. Direct observation of spin-torque driven magnetization reversal through nonuniform modes. Phys. Rev. Lett. 100, 247201 (2008). 71. Bryan, M. T., Fry, P. W., Fischer, P. J. & Allwood, D. A. Observation of field-induced domain wall propagation in magnetic nanowires by magnetic transmission X-ray microscopy. J. Appl. Phys. 103, 07D909 (2008). 72. Meier, G. et al. Direct imaging of stochastic domain-wall motion driven by nanosecond current pulses. Phys. Rev. Lett. 98, 187202 (2007). 73. Argyle, B. E., Terrenzio, E. & Slonczewski, J. C. Magnetic vortex dynamics using the optical Cotton-Mouton effect. Phys. Rev. Lett. 53, 190–193 (1984). 74. Thiele, A. A. Steady-state motion of magnetic domains. Phys. Rev. Lett. 30, 230–233 (1973). 75. Huber, D. L. Equation of motion of a spin vortex in a two-dimensional planar magnet. J. Appl. Phys. 53, 1899–1900 (1982). 76. Okuno, T., Shigeto, K., Ono, T., Mibu, K. & Shinjo, T. MFM study of magnetic vortex cores in circular permalloy dots: behavior in external field. J. Magn. Magn. Mater. 240, 1–6 (2002). 77. Thiaville, A., Garcia, J. M., Dittrich, R., Miltat, J. & Schrefl, T. Micromagnetic study of Bloch-point-mediated vortex core reversal. Phys. Rev. B 67, 094410 (2003). 78. Van Waeyenberge, B. et al. Magnetic vortex core reversal by excitation with short bursts of an alternating field. Nature 444, 461–464 (2006). 79. Xiao, Q. F., Rudge, J., Choi, B. C., Hong, Y. K. & Donohoe, G. Dynamics of vortex core switching in ferromagnetic nanodisks. Appl. Phys. Lett. 89, 262507 (2006). 80. Hertel, R., Gliga, S., Fähnle, M. & Schneider, C. M. Ultrafast nanomagnetic toggle switching of vortex cores. Phys. Rev. Lett. 98, 117201 (2007). 81. Lee, K. S., Guslienko, K. Y., Lee, J. Y. & Kim, S. K. Ultrafast vortex-core reversal dynamics in ferromagnetic nanodots. Phys. Rev. B 76, 174410 (2007). 82. Yamada, K. et al. Electrical switching of the vortex core in a magnetic disk. Nature Mater. 6, 269–273 (2007). 83. Kim, S. K., Choi, Y. S., Lee, K. S., Guslienko, K. Y. & Jeong, D. E. Electric-current-driven vortex-core reversal in soft magnetic nanodots. Appl. Phys. Lett. 91, 082506 (2007). 84. Curcic, M. et al. Polarisation selective magnetic vortex dynamics and core reversal in rotating magnetic fields. Phys. Rev. Lett. 101, 197204 (2008). 85. Zagorodny, J. P., Gaididei, Y., Mertens, F. G. & Bishop, A. R. Switching of vortex polarization in 2D easy-plane magnets by magnetic fields. Eur. Phys. J. B 31, 471–487 (2003). 86. Kravchuk, V. P., Sheka, D. D., Gaididei, Y. & Mertens, F. G. Controlled vortex core switching in a magnetic nanodisk by a rotating field. J. Appl. Phys. 102, 043908 (2007). 87. Kim, S. K., Lee, K. S., Yu, Y. S. & Choi, Y. S. Reliable low-power control of ultrafast vortex-core switching with the selectivity in an array of vortex states by in-plane circular-rotational magnetic fields and spin-polarized currents. Appl. Phys. Lett. 92, 022509 (2008). 88. Bolte, M. et al. Time-resolved X-ray microscopy of spin-torque-induced magnetic vortex gyration. Phys. Rev. Lett. 100, 176601 (2008). 89. Sandford, S. A. et al. Organics captured from comet 81P/Wild 2 by the Stardust spacecraft. Science 314, 1720–1724 (2006). 90. Maria, S. F., Russell, L. M., Gilles, M. K. & Myneni, S. C. B. Organic aerosol growth mechanisms and their climate-forcing implications. Science 306, 1921–1924 (2004). 91. Li, L. et al. X-ray microscopy studies of protein adsorption on a phase segregated polystyrene/polymethylmethacrylate surface. 2. Effect of pH on site preference. J. Phys. Chem. B 112, 2150–2158 (2008). 92. Si, M. et al. Compatibilizing bulk polymer blends by using organoclays. Macromolecules 39, 4793–4801 (2006). 93. Zhang, W. H. et al. Effect of methyl methacrylate/polyhedral oligomeric silsesquioxane random copolymers in compatibilization of polystyrene and poly(methyl methacrylate) blends. Macromolecules 35, 8029–8038 (2002). 94. Chao, W. L., Harteneck, B. D., Liddle, J. A., Anderson, E. H. & Attwood, D. T. Soft X-ray microscopy at a spatial resolution better than 15 nm. Nature 435, 1210–1213 (2005). 95. Jefimovs, K. et al. Zone-doubling technique to produce ultrahigh-resolution x-ray optics. Phys. Rev. Lett. 99, 264801 (2007). 96. Miao, J. W., Charalambous, P., Kirz, J. & Sayre, D. Extending the methodology of X-ray crystallography to allow imaging of micrometre-sized non-crystalline specimens. Nature 400, 342–344 (1999). 97. McNulty, I., Kirz, J. & Jacobsen, C. High resolution imaging by Fourier transform X-ray holography. Science 256, 1009–1012 (1992). 98. Neutze, R., Wouts, R., van der Spoel, D., Weckert, E. & Hajdu, J. Potential for biomolecular imaging with femtosecond X-ray pulses. Nature 406, 752–757 (2000). 99. Chapman, H. N. et al. Femtosecond diffractive imaging with a soft-X-ray free-electron laser. Nature Phys. 2, 839–843 (2006). 100. Feldhaus, J., Arthur, J. & Hastings, J. B. X-ray free-electron lasers. J. Phys. B 38, S799–S819 (2005). 101. Thibault, P. et al. High-resolution scanning X-ray diffraction microscopy. Science 321, 379–382 (2008). 102. Chapman, H. N. Focus on X-ray diffraction. Science 321, 352–353 (2008). 103. Araki, T. et al. Soft X-ray resonant scattering of structured polymer nanoparticles. Appl. Phys. Lett. 89, 124106 (2006). 104. Wang, C., Araki, T. & Ade, H. Soft X-ray resonant reflectivity of low Z material thin films. Appl. Phys. Lett. 87, 214109 (2005). 105. Wang, C. et al. Resonant soft X-ray reflectivity of organic thin films: Capabilities and limitations. J. Vac. Sci. Technol. A 25, 575–586 (2007). acknowledgements We are grateful to J. Stöhr, R. Fink, A. P. Hitchcock, M. Pézolet, C. McNeill, Y. Acremann and H. Chapman for providing us with figures and A. P. Hitchcock for commenting on a draft document. H.A. is supported by the US Department of Energy under contract DE-FG02-98ER45737. nmat_2399_APR09.indd 290 13/3/09 11:54:49 © 2009 Macmillan Publishers Limited. All rights reserved