Model Reversion:A Client Slider qty Model Latte 2nd Lifter qty Part name GUIDE Gate type: Side gate 2NDINPUTTRA YRIGHT-MP Part no Cavities dfm by Yao lichun 2/3 Plate
Model Reversion : A Client : Slider qty : 1 Model : Latte 2nd Lifter qty : 0 Part name : GUIDE- 2NDINPUTTRAYRIGHT-MP Gate type : Side gate Part no.. : Cavities : 2 DFM by : Yao Lichun 2/3 Plate : 2
ICAL 1- Date of opening (all dates in 2005) CAL 2- Date of beginning of action 3.- Date foreseen for validation DEM follow-up issue. Integral Corrective Action List 4. Date of validation( closing) Page Solutions / Action Who Gate(mold flow) Waiting for confirmatio 07/0907/090709 Parting line aiting for confirmation 07/0907/09 P5 Slider Waiting for confirmation. 070907/090709 P6 Waiting for confirmation 07/0907/090709 iting for confirmation 07/09 8 Draft angle Waiting for confirmation 07/0907/09 07/09 P 9 Draft angle aiting for confirmation 07/09070907/09 Draft angle Waiting for confirmation P 11 Texture Waiting for confirmation 07/0907/09
ICAL ICAL 1 - Date of opening (all dates in 2005) 2 - Date of beginning of action 3.- Date foreseen for validation DFM follow-up issue. Integral Corrective Action List 4 . Date of validation( closing) Page Open points Solutions / Action Who 1 2 3 4 P.3 Gate (mold flow) Waiting for confirmation. 07/09 07/09 07/09 P.4 Parting line Waiting for confirmation. 07/09 07/09 07/09 P.5 Slider Waiting for confirmation. 07/09 07/09 07/09 P.6 Suggestion Waiting for confirmation 07/09 07/09 07/09 P.7 Suggestion Waiting for confirmation 07/09 07/09 07/09 P.8 Draft angle Waiting for confirmation 07/09 07/09 07/09 P.9 Draft angle Waiting for confirmation 07/09 07/09 07/09 P.10 Draft angle Waiting for confirmation 07/09 07/09 07/09 P.11 Texture Waiting for confirmation 07/09 07/09 07/09
Gate(mold flow) =1.B72Is Side gate moldFlow
Gate (mold flow) Side gate
Parting line The red line is part line
Parting line The red line is part line
Slider Slider
Slider
Suggestion These poles too thick, it will cause sink mark The red ribs are too thick it will cause snk mark, suggest cut plastic and keep 1. 4mm at ribs' bottom 1.2mm at ribs'top
Suggestion The red ribs are too thick, it will cause sink mark, suggest cut plastic and keep 1.4mm at ribs’ bottom, 1.2mm at ribs’ top. These poles too thick, it will cause sink mark
Suggestion Thin steel here 1.0
Suggestion 1.0 Thin steel here
Draft angle There are will be step We suggestion cut the red area plastics I degree for cavity and cut the blue shade plastics 0.5 degree for core
Draft angle We suggestion cut the red area plastics 1 degree for cavity and cut the blue shade plastics 0.5 degree for core There are will be steps
Draft angle Add 5 degree on all red surfaces(reduce plasti
Add 5 degree on all red surfaces (reduce plastic). Draft angle
Draft angle 1. For the other ribs, side surface in the cavity slider, we will make a draft angle less than 2 degree (reduce plastic) 2. For the other ribs. side surface in the core we will make a draft angle less than 1 degree(reduce plastic)
Draft angle 1. For the other ribs, side surface in the cavity & slider, we will make a draft angle less than 2 degree (reduce plastic). 2. For the other ribs, side surface in the core, we will make a draft angle less than 1 degree (reduce plastic)