当前位置:高等教育资讯网  >  中国高校课件下载中心  >  大学文库  >  浏览文档

《Microelectronics Process》MEMS LAB SESSION 3

资源类别:文库,文档格式:PDF,文档页数:2,文件大小:25.51KB,团购合买
In this lab session, the cantilever and fixed-fixed beams will be mechanically tested to determ material and device performance characteristics. The structures will be mechanically loaded the corresponding deflection measured. From the load versus deflection curves, an effective
点击下载完整版文档(PDF)

MEMS LAB SESSION 3 (Mechanical Characterization) OVERVIEW OF LAB SESSION: In this lab session, the cantilever and fixed-fixed beams will be mechanically tested to determ material and device performance characteristics. The structures will be mechanically loaded the corresponding deflection measured. From the load versus deflection curves, an effective spring constant can be calculated. This spring constant is used to analytically determine a fundamental material property, the Young's Modulus, of the silicon nitride. etermine a LAB OBJECTIVES This lab session has the following primary objectives Cleave wafers to prepare samples for testing Perform load versus deflection tests on silicon nitride beams act s pring constant. Calculate the Youngs Modulus, a basic material property, of the silicon nitride Initial instruction on the following major piece of lab equipment Hysitron Triboindenter LAB PROCEDURES MEMS Lab Session 3 has 2 major steps 3.1 CLEAVE WAFER MOUNT DIE 3.1.1 Tool: Diamond Scribe 3. 1.2 USing the diamond scribe, carefully push down on the edges of the wafer at the ends of dice lanes to separate the wafer into individual dies. Pick groups of four dies from different parts of wafers to be glued to a 1"x 1 "steel (not stainless steel) mounting plate. It is important that the plate be magnetic 3.2 LOAD VS DEFLECTION TEST 3.2.1 Tool: Hysitron Triboindenter 3.2.2 Since we will be deflecting the beams versus actually indenting them, use a conical shaped diamond tip with a 10 micron radius of curvature. If necessary, do an air indent to calibrate the piezoelectric transducer that moves the indenter tip. Trace pure Al sample to set the x-y safety limits for the stage movement. Make a H-shape Pattern to calibrate the x-y stage offset(this yields the registration between the tip and the optical microscope employed to image the cantilevers). Finally find the cantilever of interest and perform a load-deflection experiment(the maximum displacement is around 5 microns and the maximum load, 10 mN) PRE-LAB QUESTIONS 1. How is the indenter transducer actuated?

MEMS LAB SESSION 3 (Mechanical Characterization) OVERVIEW OF LAB SESSION: In this lab session, the cantilever and fixed-fixed beams will be mechanically tested to determine material and device performance characteristics. The structures will be mechanically loaded and the corresponding deflection measured. From the load versus deflection curves, an effective spring constant can be calculated. This spring constant is used to analytically determine a fundamental material property, the Young’s Modulus, of the silicon nitride. LAB OBJECTIVES: This lab session has the following primary objectives: ¾ Cleave wafers to prepare samples for testing. ¾ Perform load versus deflection tests on silicon nitride beams. ¾ Extract spring constant. ¾ Calculate the Young’s Modulus, a basic material property, of the silicon nitride. ¾ Initial instruction on the following major piece of lab equipment: Diamond Scribe Hysitron TriboIndenter LAB PROCEDURES: MEMS Lab Session 3 has 2 major steps: 3.1 CLEAVE WAFER & MOUNT DIE 3.1.1 Tool: Diamond Scribe 3.1.2 Using the diamond scribe, carefully push down on the edges of the wafer at the ends of dice lanes to separate the wafer into individual dies. Pick groups of four dies from different parts of wafers to be glued to a 1” x 1” steel (not stainless steel) mounting plate. It is important that the plate be magnetic. 3.2 LOAD VS. DEFLECTION TEST 3.2.1 Tool: Hysitron TriboIndenter 3.2.2 Since we will be deflecting the beams versus actually indenting them, use a conical shaped diamond tip with a 10 micron radius of curvature. If necessary, do an air indent to calibrate the piezoelectric transducer that moves the indenter tip. Trace a pure Al sample to set the x-y safety limits for the stage movement. Make a H-shaped Pattern to calibrate the x-y stage offset (this yields the registration between the tip and the optical microscope employed to image the cantilevers). Finally find the cantilever of interest and perform a load-deflection experiment (the maximum displacement is around 5 microns and the maximum load, 10 mN). PRE-LAB QUESTIONS: 1. How is the indenter transducer actuated? Page 1 of 2

2. Why is the periphery of the aluminum sample traced 3. What is the maximum spring constant that can be measured by the Hysitron Triboindenter? 4. What is the relationship between the effective spring constant and Young's modulus for a cantilever beam? For a fixed-fixed beam? Page 2 of 2

2. Why is the periphery of the aluminum sample traced? 3. What is the maximum spring constant that can be measured by the Hysitron TriboIndenter? 4. What is the relationship between the effective spring constant and Young’s modulus for a cantilever beam? For a fixed-fixed beam? Page 2 of 2

点击下载完整版文档(PDF)VIP每日下载上限内不扣除下载券和下载次数;
按次数下载不扣除下载券;
24小时内重复下载只扣除一次;
顺序:VIP每日次数-->可用次数-->下载券;
已到末页,全文结束
相关文档

关于我们|帮助中心|下载说明|相关软件|意见反馈|联系我们

Copyright © 2008-现在 cucdc.com 高等教育资讯网 版权所有